Valve installation, operation and maintenance manual
This manual is the installation, operation and maintenance manual for Vexve steel ball valves. The fully welded steel ball valve (colour blue) is designed for clean mediums in district heating and district cooling pipelines, and is also suitable for heating and cooling systems with oxygen-free water and oil piping systems.
It covers valve identification, unloading and storage, installation with weld or flange connections, gear and actuator disassembly and installation, maintenance, and appendices. A full bore ball valve follows the instructions for a one size larger reduced bore ball valve.
| Intended media | Clean mediums; district heating and district cooling; heating and cooling systems with oxygen-free water; oil piping systems |
|---|---|
| Temperature and pressure | Maximum allowable working pressure depends on operating temperature |
| Nominal size range | DN 10–800 |
| Storage | Open position; maximum recommended storage time is two years |
| Welding rod | ESAB OK 48.00 or equal |
They are designed for clean mediums in district heating and district cooling pipelines, heating and cooling systems with oxygen-free water, and oil piping systems.
Store it in the open position in a dry, well-ventilated place; the maximum recommended storage time is two years.
Use lifting ropes or lifting lugs; do not lift the valve by its actuator or stem.
Use manual metal arc welding with ESAB OK 48.00 or an equal welding rod.