Vexve ACGE and ACG loading group manual introduces the features and specifications of Vexve ACGE electrically operated loading group and Vexve ACG thermally operated loading group.
This manual covers the Vexve ACGE electrically operated loading group and the Vexve ACG thermally operated loading group. It lists the product numbers for the DN25, DN32 and CU 28 mm versions, gives the maximum temperature and pressure values, and describes the main components: the mixing or thermostatic valve, the loading pump, the union valves, the CTS actuator and adapter, and the temperature sensor T1.
The document explains the RIGHT and LEFT operation principles, the AM-CTS controller settings (temperature adjust knob on the front cover, sensitivity and opening direction under the cover), the flow rates at the three pump speed settings, and the parts list for the valve assembly, including the wax element, thermostatic element disc and O-rings. Contact details for Vexve Oy in Finland are given at the end.
| Maximum temperature | 110 °C |
|---|---|
| Maximum pressure | 10 bar |
| Return water temperature range | 10–80 °C, freely adjustable |
| Loading pump maximum flow | 2600 l/h, three speed settings |
| ACGE product numbers | DN25 1410070 / DN32 1410071 / CU 28 mm 1410072 |
| ACG product numbers, 55/61 °C | DN25 1410050 / DN32 1410051 / CU 28 mm 1410052 |
| ACG product numbers, 72/80 °C | DN25 1410060 / DN32 1410061 / CU 28 mm 1410062 |
| ACG opening temperatures | 55/61 °C standard, 72/80 °C also available |
| CTS actuator supply | 24 VAC 50/60 Hz |
| Adapter | 230 VAC 50/60 Hz, 300 mA, 2.5 m cable |
| Loading pump | Grundfos UPS2 25-40/60, 7-48 W, 230 VAC 50 Hz |
The loading group is rated for a maximum temperature of 110 °C and a maximum pressure of 10 bar.
The temperature adjust knob is on the front cover; the factory default is a 60-degree return temperature.
The ACGE is electrically operated and uses the Vexve CTS constant controller; the ACG is thermally operated with a thermostatic element.
Yes, changing the operation position is possible when the valve is pressurized without opening the valve.
The document specifies a Grundfos UPS2 25-40/60, 7-48 W, 230 VAC 50 Hz pump.