Huegli-Tech HT-DDD100 Digital Dual Driver Governor Instruction Manual

The HT-DDD100 is a digital dual driver governor with the following features: - Dual channel output, each channel with a maximum current of 100A - Supports fixed speed, variable speed and external potentiometer speed control - With functions such as idle, gain, current limit, EGT shutdown, etc. - Parameters can be set and monitored via PC software


Huegli-Tech HT-DDD100 Digital Dual Driver Governor Instruction Manual - cover page
Brand
Huegli Tech
Category
Other device
Document type
User Manual
Language
English
Pages
31
File format
PDF
File size
1.5 MB
Published
16 November, 2023
Updated
16 November, 2023
MD5 checksum
943CD5350D2EAC59732D21050766C257

About this manual

The Huegli-Tech HT-DDD100 is a digital dual driver governor for controlling motor rotation speed on single engines that require dual fuel pumps or throttle body actuators. It uses feedback from master and slave actuators, master and slave temperature sensors, and a magnetic RPM sensor, and can operate in isochronous or static mode.

The manual covers installation and connection, keypad and PC software use, motor starting and tuning, configurable parameters, fault correction, and technical data.

What's inside

  • Installation and connection
  • Connection terminals
  • Electrical connection
  • Hardware use (Keypad)
  • Installation of PC software
  • Software use
  • Starting the motor
  • Correction system faults
  • Technical Data
  • Dimensions

Specifications

Supply voltage12-24 VDC
Speed controlExact (<0.25%) isochronous rotation speed control
Battery positive input fuse8 A
Battery and actuator cable cross-section1.5 mm² for 24 VDC or 2.5 mm² for 12 VDC

Frequently asked questions

What does the HT-DDD100 control?

It controls motor rotation speed on single engines that require dual fuel pumps or throttle body actuators.

What voltage range does the governor support?

The governor supports a supply voltage range of 12-24 VDC.

How must overspeed protection be handled?

An overspeed shut down mechanism must be installed separately from the control system.

How should the RPM sensor be spaced from the flywheel?

Rotate the sensor in until the flywheel clicks, then rotate it out again for 3/4 of a rotation.