HWV-04C Instruction Manual Comparator Relay Output/Buzzer/Contact Input Interface

This document describes the features and specifications of the HVW-04C Instruction Manual Comparator Relay Output/Buzzer/Contact Input Interface.


HWV-04C Instruction Manual Comparator Relay Output/Buzzer/Contact Input Interface - cover page
Category
Other products
Document type
User Manual
Language
English
Pages
1
File format
PDF
File size
166 KB
Published
16 November, 2023
Updated
16 November, 2023
MD5 checksum
7597831FDB05B304C4C3E07C9A1348EB

About this manual

HVW-04C is an optional interface installed on a scale. It provides comparator relay outputs, a buzzer, and contact input terminals.

The manual lists solid-state relay output limits and explains buzzer setup, including which outputs are used in three-level comparator mode.

What's inside

  • Comparator relay output terminal
  • Contact input terminal
  • Solid state relay output specifications
  • Attached terminal (accessory of HVW-04C)
  • Buzzer setting
  • Caution

Specifications

Maximum voltage50 V DC
Maximum current100 mA DC
Maximum ON resistance8 Ω

Frequently asked questions

What is the maximum current of the solid state relay outputs?

The maximum current is 100 mA DC.

Which comparator outputs are used in three-level comparator mode?

Pins 1 (HIHI), 3 (OK), and 5 (LOLO) are used; pins 2 (HI) and 4 (LO) are not used.

How can the buzzer be set to sound for a comparison result?

Select the corresponding numerical key to turn the LED for that result on or off.

Download PDF (166 KB)