The document is an installation guide for G Series CD players. It includes safety instructions, warnings, and installation instructions.
This installation guide covers the Meridian G07 24-bit CD Player and G08 24-bit Upsampling CD Player. It describes product differences, specifications, unpacking, audio and communications connections, reset procedures, troubleshooting, and maintenance.
The guide also includes safety instructions, accessory lists, rear-panel connection descriptions, cleaning and fuse replacement notes, and service and guarantee information.
| THD | G07: less than 0.003%; G08: less than 0.0025% |
|---|---|
| Noise | G07: better than -99dB A weighted; G08: better than -100dB A weighted |
| Mechanism | G07: triple-beam laser; G08: ATAPI ROM drive |
| DSP | Upsampling using 150MIPS Motorola DSP56367 |
| Converters | 192kHz capable, 24-bit, dual differential, Delta-Sigma, superb Class A analogue design |
| Outputs | G07: digital S/PDIF coax and optical at 44.1kHz; analogue 2.3V RMS at 44.1kHz. G08: digital S/PDIF coax and optical at 88.2kHz or 44.1kHz; analogue 2.3V RMS at 176.4kHz; balanced 4.6V RMS at 176.4kHz |
| Communications | 2 5-pin 240 degree DIN sockets, BNC socket, RS232 interface |
| Formats | G07: CD Audio (CD-DA), CD-R, CD-RW. G08: CD Audio (CD-DA), CD-R, CD-RW, MP3 |
| Power | G07: transformer, fixed for local voltages, 50/60Hz, 25VA. G08: universal supply, 100-240Vac, 50/60Hz, 25VA |
| Dimensions | 440mm x 90mm x 350mm (17.32" x 3.54" x 13.78") WHD |
| Weight | 9kg (20lb) approx. |
| Controls | Front-panel soft keys include Play, Stop, Pause, Previous, Next, etc.; power button; Open/Close tray button; full remote control via MSR+ |
| Display | Multi-character Vacuum Fluorescent Display |
| Index points | Not supported |
It applies to the G07 24-bit CD Player and the G08 24-bit Upsampling CD Player.
The supplied accessories include the MSR+ remote control with batteries, manual, and spare key caps, a Meridian Comms lead, power cord, this manual, and the Meridian G Series System Guide.
Wipe it with a dry, lint-free cloth; greasy marks can be removed with a slightly damp cloth and a trace of proprietary glass cleaner.
The fuse drawer specifies T160mAL for 100-120V and T80mA for 220-240V.