Simpson Hawk 3 H340 4 Digit Advanced Temperature Digital Controller Operator's Manual

The Hawk 3 is an advanced digital controller with a 4-digit display and an H340 temperature sensor. It is designed to prevent accidental electric shock to the operator when properly used. The Hawk 3 complies with all applicable safety standards and is independently tested and certified.


Simpson Hawk 3 H340 4 Digit Advanced Temperature Digital Controller Operator's Manual - cover page
Brand
Simpson
Category
Temperature monitor
Document type
User Manual
Language
English
Pages
24
File format
PDF
File size
1.2 MB
Published
16 November, 2023
Updated
16 November, 2023
MD5 checksum
DD1474C2BE1FE28AED2850431847E61F

About this manual

The Simpson Hawk 3 H340 is a 4-digit advanced digital panel meter and controller with a red 7-segment LED display and five user-programmable brightness levels. The manual describes front-panel programming for parameters including relay control, display control, measurement control, output control, and system control; the display can show up to four activated setpoint indicators.

The document also covers installation in a 1/8 DIN panel cutout, removing and installing option modules, operating the keys, temperature input cards, menu flowchart, menu detail, and ordering information.

What's inside

  • Introduction
  • Display and Keypad Controls
  • Installation and Panel Cutout
  • Removing / Installing Option Modules
  • Operating the Keys
  • Programming Menu
  • Temperature Input Cards
  • Menu Flowchart
  • Menu Detail
  • Ordering Information

Specifications

Display Type7-segment, red LED, 4 digits
Display Height0.56” (14.2mm)
AC Power Requirements85 to 250 VAC/120 VAC @ 10VA
DC Power Requirements9 to 36 DCV @ 10VA
Operating Temperature0 to 50°C
Storage Temperature-10 to 60°C
Sample Rate10 conversions per second
Display RateUser programmable from 1/minute - 8/seconds
Panel Cutout1.77” (45mm) high by 3.62” (92mm) wide

Frequently asked questions

What are the AC power requirements?

The AC power requirement is 85 to 250 VAC/120 VAC at 10VA.

What does the display show if the sensor breaks?

The display reads “EEEE” to indicate burnout.

What panel cutout size is required?

The controller requires a panel cutout 1.77 inches high by 3.62 inches wide.

What is the sample rate?

The sample rate is 10 conversions per second.

Download PDF (1.2 MB)