This paper introduces an elevator guide rail straightness detection device, which includes a base, a guide rail installed on the base, a slider installed on the guide rail, a sensor installed on the slider, and a display installed on the sensor. The device can measure the straightness of the guide rail and display it on the display. The device can be used to detect the straightness of the elevator guide rail to ensure the quality of the elevator guide rail.
This is a conference paper from the Journal of Physics: Conference Series 2196 (2022) 012012, written by Shuangchang Feng, Yanchun Liang and Jie Chen of the Shanghai Institute of Special Equipment Inspection and Technical Research. It presents a straightness detection device for elevator guide rails, a measurement that has to be carried out when an elevator is installed. The paper first reviews existing methods, namely the vertical line method and the RSU (elevator guide rail straightness dynamic detector) method, and lists their drawbacks.
The paper then sets out the technical scheme of the proposed device: an upper infrared component fixed to the top of the uppermost guide rail with a T-shaped connecting sleeve and a locking screw, and scale assemblies that are held on the guide surface by magnets and carry transparent acrylic plates with circular dials. It explains the working principle, in which the infrared rays pass through the acrylic plates so that any offset of an intermediate guide rail can be read against the dial center, and it argues that the device is cheaper, more accurate and easier to store than the vertical line and RSU methods. The text is accompanied by an overall structure diagram and a structural diagram of the upper infrared component.
| Guide rail connecting sleeve cross-section | T-shaped, matching the guide rail cross-section |
|---|---|
| Number of infrared emitters | Two, arranged side by side |
| Emitter orientation | Placed vertically, emitting downward |
| Number of dials on the acrylic plate | Two annular dials |
| Scale assembly fastening | Adsorbed on the guide surface by a magnet |
| Example spacing between scale assemblies | 2.5 m |
It has two infrared emitters, mounted side by side on the lower surface of the infrared mounting bracket so that their emission faces downward.
A clamping groove on the acrylic plate matches the guide surface and is adsorbed onto it by a magnet.
The paper suggests installing them at equal distances, giving 2.5 m as an example.
The infrared ray passes through all acrylic plates, so when an intermediate guide rail is offset it can be read from the shift of the infrared penetration point relative to the center of the dial.