Schaudt EBL 208 S G Electrobloc Instruction Manual

The document is an instruction manual for the Electrobloc EBL 208 S G from Schaudt GmbH.


Schaudt EBL 208 S G Electrobloc Instruction Manual - cover page
Brand
Schaudt
Category
Automotive supplies
Document type
User Manual
Language
English
Pages
12
File format
PDF
File size
459 KB
Published
16 November, 2023
Updated
16 November, 2023
MD5 checksum
CDD286E43E32AE80D26A08F090A01781

About this manual

The Schaudt Electrobloc EBL 208 S G is an electrical management system for motorhomes and caravans, combining a charger module, 12 V distribution, fuses, battery monitor, and control functions. It operates on 230 V AC mains and supports lead-acid or lead-gel batteries of at least 55 Ah.

The manual covers safety information, operation of the battery cut-off switch and battery selector switch, charging via mains, solar, and alternator, maintenance, troubleshooting, and technical specifications including charging curves and voltage thresholds.

What's inside

  • Introduction
  • Safety information
  • Description and appropriate use
  • Suitable accessories
  • Technical data
  • Operation
  • Maintenance
  • Shutting down the system
  • Changing the battery
  • Technical faults, possible causes and remedies

Specifications

Mains connection230 V AC ± 10%, 47–63 Hz sinusoidal, protection class I
Suitable batteries6-cell lead acid or lead gel batteries, at least 55 Ah
Closed circuit currentApprox. 1 mA with control panel
Living area battery charging curveIUoU
Living area battery final charging voltage14.3 V
Living area battery charging current18 A
Living area battery float charge voltage13.8 V with automatic switching
Starter battery float charge currentMax. 2 A
Solar charging max current14 A (fuse-protected by 15 A fuse)
Battery monitor breaking voltageApprox. 10.5 V
Battery monitor minimum voltage for 12 V main switchApprox. 11.0 V

Frequently asked questions

What is the mains voltage requirement for the Electrobloc EBL 208 S G?

The Electrobloc requires a 230 V AC ± 10%, 47–63 Hz sinusoidal mains supply with protection class I.

Which battery types are compatible with the Electrobloc EBL 208 S G?

It supports 6-cell lead acid or lead gel batteries with a capacity of at least 55 Ah.

What is the charging current for the living area battery when connected to mains?

The living area battery is charged at 18 A using the IUoU charging curve.

What is the breaking voltage of the battery monitor?

The battery monitor breaks at approximately 10.5 V.