Instruction manual for the Schaudt EBL 101 D / EBL 101 C Electroblock with OVP, covering safety, operation, battery changes, faults, and maintenance.
The Schaudt EBL 101 D / EBL 101 C with OVP Electroblock is intended for installation in a vehicle and is operated from a connected DT ... control and switch panel, apart from battery isolation. The manual explains safety information, switching the system on and off, changing the battery, handling operating faults, closing down the system, and maintenance.
The document also describes application and functions in detail, including battery functions, additional functions, and use as an exchange device. It includes instructions for setting the battery selector switch for lead gel or lead acid batteries.
| Mains voltage | 230V AC |
|---|---|
| Battery type | 6-cell lead gel or lead acid |
| Battery selector setting | Lead-gel |
After disabling battery isolation or changing batteries, briefly turn on the 12V main switch on the DT ... control and switch panel to start the consumers. The main 12V switch is used to switch all consumers and the control and switch panel on and off.
It is intended for 12V power supplies with rechargeable 6-cell lead gel or lead acid batteries; unsuitable battery types should not be used.
For AGM batteries, moving the battery selector switch to the Lead Gel position is recommended. Suitability must still be checked case by case using the battery manufacturer's specifications and the Electroblock charging parameters.
Swapping lead acid batteries with lead gel batteries is possible. Changing from lead gel batteries to lead acid batteries is not possible without overhead; contact the vehicle manufacturer for more information.