The document is about the user manual of a refrigerator.
This Elkay Installation, Care & Use Manual covers the EWCDA*B and EWCA14*1F water coolers. It provides installation dimensions, recommended mounting heights, ventilation requirements, and water supply and drain locations.
The manual also includes stream height adjustment instructions, a WaterSentry filter parts list, panel color options, a full replacement parts list, and repair service contact information.
| Refrigerant | HFC-134A |
|---|---|
| Recommended height for adults | 40" (1016mm) |
| Recommended height for children | 33" (838mm) |
| Minimum ventilation clearance | 4" (102mm) |
| Factory stream height | 35 PSI |
| Power cord length | 1-1/2' (457mm) |
It uses HFC-134A refrigerant.
The recommended height is 40" (1016mm).
Maintain a minimum of 4" (102mm) clearance from cabinet louvers to the wall.
The stream height is factory set at 35 PSI.