EZ & LZ Series Versatile Bottle Filling Stations & Coolers Installation, Care & Use Manual

This document provides installation, care and use instructions for the EZ™ & LZ™ Series Versatile Bottle Filling Stations & Coolers.


EZ & LZ Series Versatile Bottle Filling Stations & Coolers Installation, Care & Use Manual - cover page
Category
water dispenser
Document type
User Manual
Language
English
Pages
18
File format
PDF
File size
3.8 MB
Published
15 November, 2023
Updated
15 November, 2023
MD5 checksum
55B791C0949516FCE991C5E8D2BE97A9

About this manual

This installation, care and use manual covers EZ and LZ Series versatile bottle filling stations and coolers, including EZSTLDWS*1D, EZSTLRDWS*1D, EZSTL8WS*1D/2D/3D, EZSTLR8WS*1D and the corresponding LZSTL models. The supplied pages show standard and alternate rough-in layouts, dimensions, water and waste connections, electrical supply locations, and ventilation clearance.

The manual notes that new installations must use a GFCI, that the unit uses HFC-R134A refrigerant, and that an optional filter is available. It also describes left-hand high/right-hand low and left-low/right-high installation configurations; a basin change may be required for the alternate arrangement.

What's inside

  • Standard Rough-In for Left-Hand High, Bottle Filler Low Models
  • Alternate Rough-In for Right-Hand High, Bottle Filler Low Models
  • Alternate Rough-In for Right-Hand High, Bottle Filler High Models
  • Legend/Leyenda/Légende
  • ADA Requirement
  • Optional Filter

Specifications

RefrigerantHFC-R134A
Water supply connection3/8 in. O.D. unplated copper tube connect stub with shut-off (by others)
Waste outlet1-1/2 in. O.D. drain stub, 2 in. out from wall
Electrical supply3-wire recessed box
GFCI requirementRequired for new installations
Minimum wall clearance6 in. (152 mm) minimum from cabinet louvers to wall

Frequently asked questions

What refrigerant is used?

The unit uses HFC-R134A refrigerant.

What clearance must be maintained from the cabinet louvers to the wall?

Maintain at least 6 in. (152 mm) clearance from cabinet louvers to the wall.

What electrical protection is required for new installations?

New installations must use a Ground Fault Circuit Interrupter (GFCI).

Can the cooler be installed in either left-hand high/right-hand low or left-low/right-high configuration?

The manual says the versatile cooler design allows either arrangement, and a basin change may be required.