AiLink Fascia Gun Application Specification

AiLink Fascia Gun User Manual introduces the usage and precautions of the fascia gun.


AiLink Fascia Gun Application Specification - cover page
Brand
AI-Link
Category
Health Care
Document type
Application Note
Language
Chinese
Pages
33
File format
PDF
File size
925 KB
Published
15 November, 2023
Updated
15 November, 2023
MD5 checksum
C48BEDDB21E53FC6F7DD6398C27F1ABA

About this manual

This document describes the application of AiLink BM16/BM02 modules in a smart fascia gun. It defines the module's operating modes (power-off, deep sleep, low-frequency broadcast, normal working), Bluetooth interface details (service UUIDs, characteristic UUIDs, broadcast data format), and the AiLink general protocol for module configuration and control. The document targets MCU developers implementing the fascia gun's smart functions via UART-to-BLE data transmission.

The specification includes interaction flows for APP binding, device start/stop, gear setting, countdown timer, and real-time status reporting. It provides concrete command frames for module version reading, CID/VID/PID setting, reset, factory reset, time setting, sleep/wake control, and auto-sleep configuration. An application example outlines module startup and shutdown sequences. This manual is written in Chinese.

What's inside

  • Revision History
  • Overview
  • Description
  • Operating Modes
  • Bluetooth Interface
  • Smart Fascia Gun
  • AiLink Protocol
  • Application Examples
  • Contact Us

Specifications

Bluetooth Name FormatAiLink_xxxx (xxxx = last 4 chars of MAC)
Fixed Service UUID0000FFE0-0000-1000-8000-00805F9B34FB
Default Custom Service UUIDFEE0
Normal Mode Broadcast Interval200 ms
Low-Frequency Broadcast Interval1 s (default)
Default Auto-Sleep Trigger3 minutes no operation
Deep Sleep Wakeup CommandA6 02 1A 01 1D 6A
Module Default VID/PID0x0000

Frequently asked questions

What is the default Bluetooth broadcast interval in normal working mode?

The default broadcast interval in normal working mode is 200 ms.

How do you wake up the module from deep sleep mode?

Send the serial command A6 02 1A 01 1D 6A to wake up the module.

What is the default auto-sleep time before entering low-frequency broadcast?

The module enters low-frequency broadcast after 3 minutes of no operation.

Which service UUIDs are used for APP interaction?

The fixed service UUID FFE0 and the customizable UUID (default FEE0) are used; AiLink APP uses FFE0.

Download PDF (925 KB)