锚杆锚固工程不但具有复杂性,还具有高度的隐蔽性,发现质量问题难,事故处理更难。因此锚杆检测工作是整个锚固工程中不可缺少的环节,只有提高锚杆监测工作的质量和监测评定结果的可靠性,才能真正地确保锚固工程的质量与安全。
This is the Chinese user manual (Version 1.0) for the Tianchen TS-ABC602 anchor rod and cable nondestructive testing instrument, made by Wuhan Tianchen Weiye Geophysical Exploration Technology Co., Ltd. The instrument uses an acoustic wave reflection method to test the length and grouting compactness of anchor bolts and cables; it consists of a main unit, a magnetostrictive acoustic source and a sensor, and it cites the standards JGJ/T 182-2009 and DL/T 5424-2009.
The manual introduces the measuring principle and product features, lists the main performance parameters and operating environment, then explains the main unit panel (USB, charging and CH1/CH2 sensor ports, power switch and photoelectric knob), charging and operation. Later chapters cover file management and the file, edit, view and analysis menus, anchor bolt modeling, printing and electronic output of data, and instrument maintenance; the final pages describe typical test waveforms for different grouting conditions. This manual is written in Chinese.
| Sampling interval | 1 to 8000 µs, adjustable |
|---|---|
| A/D sampling | 24-bit with floating-point amplification |
| Display | 8-inch 800×480 true-color LCD, 160,000 colors |
| Power supply | DC 11.1 V, built-in high-energy lithium battery, 36 hours continuous operation per charge |
| Dimensions and weight | 260 mm × 190 mm × 70 mm, 1.8 kg |
| Protection rating | IP54 |
| Data interface | USB 2.0; built-in 32 GB memory, FAT32 format |
| Operating environment | Temperature −20 °C to 60 °C, relative humidity ≤90%, atmospheric pressure 80–106 kPa |
| Length uncertainty | <1% (bolt length greater than 1 m and less than 100 m) |
| Amplitude linearity | ±0.3 dB/6 dB |
| Working current | Less than 1.5 A at 11.1 V DC |
It tests the quality of newly installed anchor bolts (bolt length and grouting compactness) and evaluates the condition of anchor bolts in long-term service, such as damage.
It uses an acoustic wave reflection method to test the length of the anchor rod or cable and the grouting compactness, combining travel time, amplitude and frequency of the signals.
The enclosure is waterproof and dustproof to IP54, and the operating temperature range is −20 °C to 60 °C.
The main unit is powered by DC 11.1 V with a built-in high-energy lithium battery and can work continuously for 36 hours per charge.