Straightpoint Wirelink Plus WLP Tension Load Cell User Manual

This product is a non-indicating tension loadcell with a capacity of 1t - 300t, capable of both weighing and dynamic load monitoring. It is designed for use with Crosby Straightpoint’s Handheld plus digital display, desktop controller PC software (DCP10M) or other form of instrumentation.


Straightpoint Wirelink Plus WLP Tension Load Cell User Manual - cover page
Brand
Straightpoint
Category
sensor
Document type
User Manual
Language
English
Pages
18
File format
PDF
File size
1.2 MB
Published
15 November, 2023
Updated
15 November, 2023
MD5 checksum
7C3F0ED1F0E540133817CAB9E80C4789

About this manual

This manual covers the Straightpoint Wirelink Plus (WLP), a non-indicating tension load cell with capacities from 1t to 300t that is capable of both weighing and dynamic load monitoring. It is designed for use with Crosby Straightpoint's Handheld plus digital display, the DCP10M desktop controller PC software, or other instrumentation.

The document includes the EU and UK declarations of conformity, general safety descriptions and warnings, and sections on the WLP six-way socket, WLP connection, WLP ICA wiring boards, product aftercare, service and calibration, and warranty. The load cell is constructed from aerospace grade aluminium with a separate internal sealed enclosure for the electronics, rated to IP67 or NEMA6, and includes a 90db audible set point alarm and RS-485 serial output.

What's inside

  • General description and warnings
  • WLP six-way socket
  • WLP connection
  • WLP ICA wiring boards
  • Product aftercare
  • Service and calibration
  • Warranty

Specifications

Capacity range1t - 300t
FunctionsWeighing and dynamic load monitoring
ConstructionAerospace grade aluminium
Environmental ratingIP67 or NEMA6
Audible alarm90db set point alarm
Serial outputRS-485
Recommended proof loadTwice the working load limit (WLL)

Frequently asked questions

What instrumentation can the WLP load cell be used with?

It is designed for use with Crosby Straightpoint's Handheld plus digital display, the DCP10M desktop controller PC software, or other forms of instrumentation.

What proof load is applied to Straightpoint load indicating products?

The recommended proof load is twice the working load limit (WLL), unless otherwise shown, and proof testing is included on all Straightpoint load indicating products.

Which standards does the WLP conform to?

It is declared in conformity with the EU Machinery Directive 2006/42/EC, EU EMC Directive 2014/30/EU and EU RoHS 2011/65/EU, with reference to standards such as EN ISO 12100:2010 and EN 61326-1.

What standard applies to detachable load indicating devices referenced in the manual?

The manual references ASME B30.26-2010 for detachable load indicating devices.

Download PDF (1.2 MB)

More Straightpoint Manuals