The ZQWL-CANET-3B111 CAN converter can convert data between CAN bus (TTL level) and Ethernet.
The ZQWL-CANET-3B111 is a compact CAN-to-Ethernet conversion module with one CAN interface and one Ethernet interface. It supports CAN baud rates from 10 kbps to 1000 kbps and can be configured through configuration software or a web page.
The manual covers hardware preparation, default parameters, pin definitions, module configuration, CAN and network transparent transmission in TCP and UDP modes, and common problems and solutions. This manual is written in Chinese.
| Model | ZQWL-CANET-3B111 |
|---|---|
| Power supply | 3.3 VDC, 50 mA |
| CPU | 32-bit high-performance processor |
| Ethernet interface | 10M/100M adaptive, 2 kV electromagnetic isolation |
| CAN interface | TTL level; requires external CAN transceiver |
| Operating temperature | -40 to 85 C |
| Humidity | 5% to 95% relative humidity |
| CAN baud rate | 10 kbps to 1000 kbps |
| TCP server clients | 4 |
| CAN receive filters | 14 groups |
| CAN and network buffer | 2000 CAN frames each |
The default IP address is 192.168.1.253.
The default username is admin.
The default password is admin.
Hold the CFG button for more than 5 seconds.