This document is about the user manual of Teka gas stove.
This Teka manual covers built-in gas stove models such as CG.1 4G, CG.1 3G.1P, CG-Lux-60 4G, CGC 4G, CG-Lux-70 5G, CG-Lux-75 2G, and CG-Lux-86 3G. It describes burners, installation, gas connection, electrical connection, gas conversion, technical data, use, cleaning, and maintenance.
It warns that hot areas can cause burns and that children should be kept away. It also states that installation and adjustment must be done by an authorized technician. This manual is written in Portuguese.
| CG.1 4G auxiliary burner output | 860 Kcal/h (1 kW) |
|---|---|
| CG-Lux-60 4G maximum heat output | 6.450 Kcal/h (7.5 kW) |
| CG.1 3G.1P electric plate | 1.500 W, Ø 145 mm |
| CG.1 3G.1P maximum electric power | 1.500 W |
| CG-Lux-70 5G TR triple crown burner output | 3.010 kcal/h (3.5 kW) |
| CG-Lux-75 2G maximum heat output | 6.020 Kcal/h (7 kW) |
| CG-Lux-86 3G maximum heat output | 7.520 Kcal/h (8.75 kW) |
Installation and adjustment must be done by an authorized technician.
The gas tap should be placed in “zero” (off).
Children should be kept away because hot areas can cause burns.