This document is about the instruction manual for washdown and water pressure system pumps.
This is the multilingual instruction manual for Jabsco HD model washdown and water pressure system pumps, published by Xylem. The English section covers the purpose of the manual, available resources, warranty and returns, installation, operation and maintenance, with the same content repeated in French and other languages.
The manual explains how to mount the pump above the water-line, install plumbing with hose clamps and a strainer, and connect it to a power source with the correct wire gauge and fuse. It describes priming and on-demand operation via the integrated pressure switch, monthly checks, and off-season draining and winterizing. Safety warnings state the pump is for fresh and salt water only, must not be used with flammable liquids, is not submersible, and is intended for intermittent duty. Xylem's limited warranty covers the product for 3 years.
| Approved fluids | Fresh water and salt water only |
|---|---|
| Wire leads | 14, 16, or 18 AWG (2.5 mm², 1.5 mm², or 1 mm²) |
| Duty cycle | Intermittent duty only |
| Recommended strainer | Jabsco 20 or 40 Mesh strainer on the intake side |
| Mounting | Horizontal, or vertical with pumphead facing down; not submersible |
The pump is designed for use with fresh water and salt water only; use with any other fluid could damage the pump and cause injury.
No, the pump is not submersible and should be bolted to a solid surface above the water-line in a dry, ventilated area.
The Xylem limited warranty covers the product against defects and workmanship for a period of 3 years.
Drain the unit by removing the intake line and running the pump until no fluid dispenses, then fill it with an appropriate anti-freeze if temperatures will go below freezing.