Installation, operation, maintenance and safety instructions for JABSCO 53080 & 53081 series utility pumps.
This manual provides detailed instructions for installing, operating, maintaining, and safely using the JABSCO 53080 & 53081 series 1½ inch 80 size 'UTILITY' pump. It covers mounting, electrical connections, priming, dry-running protection, and safety precautions. The document also includes a parts list and service instructions for disassembly and reassembly. Electrical safety is emphasized, including grounding requirements and voltage considerations for 110V units. The manual warns against pumping flammable or hazardous liquids and provides guidance on handling hazardous substances under COSHH regulations. This manual is written in Chinese.
| Impeller Material | Neoprene or Nitrile |
|---|---|
| Maximum Discharge Pressure | See pump data sheet |
| Dry-Running Protection | Up to 30 minutes |
The pump can operate in any position, but for full dry-running protection, it should be mounted on a horizontal surface.
The supply voltage during start-up should not fall below 104 volts measured at the motor.
Do not use this pump for petrol, toluene, benzene, or light fraction petroleum products with a flash point below 37°C.
The producer’s instructions must be observed, and the chemical composition must be stated when returning pumps for repair or examination.