This document describes the features and specifications of the 053410_09 09 2013_V1 model.
This user manual describes the GYS Powerduction 053410 induction heater. It states that the machine is semi-automatic, requires the presence of an operator, and is intended only to generate heat within ferrous materials.
The manual covers warranty, safety notes, product specifications, dimensions, control panel indicators, operating steps, inductor replacement, maintenance, electrical diagrams, cooling liquid circuit diagrams, and compliance declarations. It also notes that alarms stop heating and that inductor replacement must be done by authorized staff after power is removed.
| Power | 5.2 kW |
|---|---|
| Voltage | 220 V |
| Mains frequency | 50 Hz |
| Heater frequency | 20-40 kHz |
| Insulation | Class F, No. of poles: 2 + T |
| Cooling liquid | Standard automotive cooling liquid (water + 30% max. glycol) |
| Mains cable | 8 m |
| Inductor cable | 3 m |
| Weight and height | 65 kg; 900 mm + 96 mm wheels |
| Width | 520 mm |
| Depth | 420 mm |
| Plug | Single phase 220V / 50 Hz plug |
| Electrical protection | Minimum protection 25A, ideally 32A |
| Fuses | 2x 32 A fuses on the heating circuitry |
| Sound pressure level | Less than 60 dB(A) for continuous use |
It is designed to generate heat within ferrous materials.
Leave the product on without using the inductor so the cooling liquid temperature can decrease.
The product does not heat up.
Only authorized staff, after removing power to the machine.