This user manual describes the GYS Powerduction 053410 induction heater. It states that the machine is semi-automatic, requires the presence of an operator, and is intended only to generate heat within ferrous materials.

The manual covers warranty, safety notes, product specifications, dimensions, control panel indicators, operating steps, inductor replacement, maintenance, electrical diagrams, cooling liquid circuit diagrams, and compliance declarations. It also notes that alarms stop heating and that inductor replacement must be done by authorized staff after power is removed.

What's inside

  • Warranty
  • Product specifications
  • Control panel description
  • Instructions of use
  • Replacing the inductor
  • Maintenance
  • Electrical diagrams
  • Cooling liquid circuit diagrams

Specifications

Power5.2 kW
Voltage220 V
Mains frequency50 Hz
Heater frequency20-40 kHz
InsulationClass F, No. of poles: 2 + T
Cooling liquidStandard automotive cooling liquid (water + 30% max. glycol)
Mains cable8 m
Inductor cable3 m
Weight and height65 kg; 900 mm + 96 mm wheels
Width520 mm
Depth420 mm
PlugSingle phase 220V / 50 Hz plug
Electrical protectionMinimum protection 25A, ideally 32A
Fuses2x 32 A fuses on the heating circuitry
Sound pressure levelLess than 60 dB(A) for continuous use

Frequently asked questions

What is the machine designed to do?

It is designed to generate heat within ferrous materials.

What should be done if the cooling liquid temperature alarm appears?

Leave the product on without using the inductor so the cooling liquid temperature can decrease.

What happens when an alarm indicator is active?

The product does not heat up.

Who may replace the inductor?

Only authorized staff, after removing power to the machine.