COVID-19 IgM/IgG Test Kit (Colloidal Gold Method) Instructions
This user manual describes the (COVID-19) IgM/IgG test kit based on the dry fluorescence immunoassay method, produced by Lansion Biotechnology Co., Ltd. The kit is intended for the in vitro diagnosis of COVID-19 IgM/IgG antibodies in human serum and plasma, and is only for use in medical institutions by professionals, either as a supplementary indicator for nucleic-acid-negative suspected cases or together with nucleic acid testing. It is not suitable for screening the general population or for self-testing, and cannot be used as a basis for diagnosing or excluding novel coronavirus pneumonia.
The manual covers the test principle, kit components (test strips, sample diluent, QR calibration card), storage at 4°C-30°C with an 18-month validity, sample requirements, the step-by-step test procedure, result interpretation with negative, gray and positive ranges for IgM and IgG, limitations, performance characteristics and precautions. The test is read on Lansion dry fluorescence immunoassay analyzers such as the LS-1000, LS-2000, LS-1100, LS-2100, LS-4000 (portable) and LS-7000. This manual is written in Spanish.
| Package specification | 25 tests/kit or 50 tests/kit |
|---|---|
| Storage temperature | 4°C - 30°C |
| Shelf life | 18 months |
| Sample volume | 5 μL of sample plus four drops of diluent (100 μL-140 μL) |
| Read time | 15 minutes after adding sample |
| IgM positive range | > 0.08 mIU/mL |
| IgG positive range | > 0.08 mIU/mL |
| Maximum interfering substance concentrations | 3 mg/ml hemoglobin, 2 mg/ml bilirubin, 10 mg/ml triglycerides |
The kit is used with human serum or plasma; plasma may be anticoagulated with EDTA. Other body fluids may not give exact results.
The strip is read on Lansion dry fluorescence immunoassay analyzers: LS-1000, LS-2000, LS-1100, LS-2100, LS-4000 (portable) and LS-7000.
Samples should be analyzed immediately after collection; serum can be stored at 2°C-8°C for 3 days, or at -20°C for long-term storage, avoiding repeated freeze-thaw cycles.
Repeat the test or perform a PCR test, and judge the patient in combination with clinical symptoms.