This document is an installation guide for the Grundfos 1 UP 10-16 PM water pump.
This document is the installation guide for the Grundfos 1 UP 10-16 PM, identified in the EC declaration of conformity as the Grundfos Comfort PM. It opens with safety warnings in English, Spanish and French, stating that the pump is intended for use with water only and that installation and operation must comply with national, state and local regulations.
The guide includes illustrated installation steps with limits such as a maximum of 145 PSI (10 bar), liquid temperature limits from 35 °F (2 °C) to 176 °F (80 °C), and installation clearances of 8 ft (2.5 m) and 8-20 inches (20-50 cm). It also describes AUTO ADAPT operation with ON/OFF settings running 24 h/365 at below 43 dB(A), and closes with a limited warranty from GRUNDFOS PUMPS CORPORATION and the EC declaration of conformity signed at Bjerringbro, Denmark.
| Maximum pressure | 145 PSI (10 bar) |
|---|---|
| Maximum head | 3.9 ft (1.2 m) |
| Liquid temperature range | 35 °F (2 °C) to 176 °F (80 °C) |
| Maximum ambient temperature | 104 °F (40 °C) |
| Noise level | < 43 dB(A) |
| Installation clearance | 8 ft (2.5 m) and 8-20 inches (20-50 cm) |
The pump is intended for use with water only.
Grundfos warrants the product to be free of defects in material and workmanship for 24 months from date of installation, but not more than 30 months from date of manufacture.
The EC declaration of conformity lists the low voltage directive (2006/95/EC) with EN 60335 standards and the EMC directive (2004/108/EC) with EN 55014 standards.
In AUTO ADAPT the pump runs with ON/OFF operation 24 h/365 at a noise level below 43 dB(A).