Models AM-50BAJ AM-50BAJ-DS AM-50BAJ-AD AM-50BAJ-ADDS Self-Contained Cuber Service Manual
This is the Hoshizaki Service Manual (Number 73218) for the AM-50BAJ, AM-50BAJ-DS, AM-50BAJ-AD, and AM-50BAJ-ADDS self-contained cuber icemakers. It is written primarily for qualified service technicians and covers construction, the water and refrigeration circuits, sequence of operation, service diagnosis, the control board, refrigeration and component service, and maintenance.
The manual also includes safety information, instructions for preparing the icemaker for periods of non-use, disposal guidance, specification and performance data, and wiring diagrams for auxiliary codes J-0 and earlier, J-1 and later, and N-0 and later, plus the optional HS-5061 drain pump.
| Normal operating ambient temperature | 45°F to 100°F (7°C to 38°C) |
|---|---|
| Thermistor resistance at 27°F (-3°C) | 6.8 kΩ or more |
| Thermistor resistance at 45°F (7°C) | 4.5 kΩ or less |
| Inlet water valve time, normal harvest | 102 sec. or the length of harvest, whichever is shorter |
| Optional drain pump | HS-5061 |
Only qualified service technicians should install and service the appliance, and they should read this Service Manual thoroughly before undertaking any service.
All correspondence must include the model number, serial number, and a complete and detailed explanation of the problem.
Within 10 seconds after ice contacts the thermostatic bulb, the bin control opens and the appliance shuts down; all components are de-energized except the bin control heater and optional drain pump.
Test its operation every time the appliance is cleaned and sanitized, since a drain pump that is not operating properly could cause water to back up and overflow.