This product is a commercial refrigerator/freezer with features such as energy saving and environmental protection, high efficiency refrigeration and simple operation.
This bilingual Chinese/English instruction manual covers Hoshizaki HRE, HFE and HRFE MA series commercial refrigerators and freezers; the construction drawings and accessory table use the HRE-127MA-CHD and list cabinet widths of 700 mm, 1200/1400 mm and 1800 mm. It starts with installation: names of parts, accessories, location requirements, set up, shelf and rail fitting, electrical connections and drain connections.
The operating instructions describe start up, the front panel, cabinet temperature setting, defrost and indicator lights, and shut down. A maintenance section covers cleaning the interior, exterior and shelves, the air filter, troubleshooting with and without error code indication, disposal and warranty. This manual is written in Chinese.
| Ambient Operating Temperature | 5 °C to 43 °C, indoor use only |
|---|---|
| Maximum Load per Shelf | 60 kg |
| Minimum Clearance at Front | 100 cm |
| Minimum Clearance to Ceiling | 30 cm |
| Adjustable Foot Height | 9 to 12 cm (15 to 18 cm on some models) |
| Ground Leakage Breaker | Rated current not less than 15 A, installed on the main power supply |
| Permissible Voltage Fluctuation | Within ±10% of the rated voltage on the nameplate |
| Compressor Start Delay | 3 minutes after the power plug is inserted |
| Defrost Drain Hose | Flexible hose 18 mm at drain port, 26 mm outer diameter at outlet |
The compressor and condenser fan motor start 3 minutes after the power plug is inserted.
The unit is for indoor use only, with a normal working ambient temperature between 5 °C and 43 °C.
Negative pressure forms inside the cabinet; wait about 30 seconds before opening it again.
Leave at least 100 cm at the front for opening and closing the doors and at least 30 cm between the top of the unit and the ceiling.