KTC STR3 Stepper Drive User Manual

The KTC-STR3 is a fully digital stepper drive that uses a DSP chip and an advanced control algorithm. It features ultra-quiet operation, low heat generation, and smoother motion.


KTC STR3 Stepper Drive User Manual - cover page
Brand
KT&C
Category
Motor
Document type
User Manual
Language
Portuguese
Pages
19
File format
PDF
File size
752 KB
Published
11 November, 2023
Updated
11 November, 2023
MD5 checksum
F674FF41D95A969FF90C2DD30809FD09

About this manual

The KTC-STR3 is a fully digital stepper motor drive based on a DSP with advanced control algorithms. It supports programmable microstep resolution up to 25,600 steps/revolution, programmable output current from 0.5 to 3.0 A RMS (4.2 A peak), and supply voltage from 24 to 50 VDC. It is compatible with 2- or 4-phase motors and supports PUL/DIR and CW/CCW control modes.

The manual covers pin assignments, control signal interfaces, motor wiring, power supply selection, resolution and current settings, physical and typical connections, protection functions, and troubleshooting. The drive includes overcurrent, overvoltage, and motor phase-error protections, with automatic idle-current reduction to 60% when the motor stops. This manual is written in Portuguese.

What's inside

  • Introduction, features and applications
  • Specifications
  • Pin assignment and description
  • Control signal connector interface
  • Motor connection
  • Power supply
  • Resolution and current selection
  • Physical connection
  • Typical connection
  • Protection functions

Specifications

Output current0.5 to 3.0 A RMS (4.2 A peak)
Supply voltage24 to 50 VDC
Pulse voltage4.5 to 28 VDC
Logic signal current7 to 16 mA
Pulse input frequency0 to 200 kHz
Insulation resistance100 MΩ
Ambient temperature0°C to 50°C
Operating temperatureup to 70°C
Storage temperature-20°C to 65°C
Humidity40%RH to 90%RH
Weightapproximately 280 g
Microstep resolutionup to 25,600 steps/revolution
Overcurrent protection threshold22 A continuous
Overvoltage protection threshold50 ± 1 VDC
Idle current reduction60% when the motor stops

Frequently asked questions

What should I do first if the drive does not work correctly?

Identify whether the problem is electrical or mechanical, then isolate the component causing it.

What can cause the motor to run in the wrong direction?

The motor phases must be inverted.

What does the red LED indicate during overcurrent protection?

It lights once within each 3-second period.

How can the drive be restarted after a protection activates?

Re-energize the drive after removing the problem.

Download PDF (752 KB)