Top Instrument CZ Series Seed Storage Cabinet User Manual

Top instrument seed storage cabinet adopts high-quality, high-efficiency and wide starting voltage range of fully enclosed compressor, with fast cooling speed and low power consumption. The door body adopts luxurious hollow glass, with better heat preservation and display effect. There is a lighting lamp on the top of the cabinet, which can ensure the lighting inside the cabinet at any time.


Top Instrument CZ Series Seed Storage Cabinet User Manual - cover page
Brand
Top Instrument
Category
Other device
Document type
User Manual
Language
Chinese
Pages
5
File format
PDF
File size
162 KB
Published
11 November, 2023
Updated
11 November, 2023
MD5 checksum
995C6FEB16799D947B5BB61DCE9A0C21

About this manual

This is the user manual (使用说明书) for the CZ Series seed storage cabinet made by Zhejiang Top Instrument Co., Ltd. (托普仪器). It describes the fully enclosed compressor, hollow-glass door and top lighting, and gives operating guidance for the temperature controller knob.

The manual lists safety precautions, transport and cleaning instructions, the model line-up (CZ-16F, CZ-10F, CZ-030F, CZ-025F with their internal volumes), a fault/cause/check/repair table for common problems, and a list of other matching Top Instrument seed-testing equipment with the company contact details. This manual is written in Chinese.

What's inside

  • 产品概述
  • 产品主要技术参数
  • 安全注意事项
  • CZ系列种子储藏柜使用说明
  • 常见故障及处理
  • 系列型号
  • 其它配套仪器

Specifications

Protection class against electric shockI
Rated voltage220 V
Rated frequency50 Hz
Storage temperature-5 to 10 °C
Permissible supply voltage range187-242 V
Internal volume (CZ-16F)1600 L
Internal volume (CZ-10F)1000 L
Internal volume (CZ-030F)300 L
Internal volume (CZ-025F)250 L

Frequently asked questions

What temperature should the thermostat knob be set to?

Setting the knob between 2 and 4 is the most suitable; 0 stops the compressor and "强冷" (maximum) runs the unit continuously, so it should not be used for long.

What happens after a power failure - can the cabinet be restarted immediately?

No, wait at least 5 minutes before starting it again after power is restored.

What items must not be stored in the cabinet?

Medicines, flammable, explosive, corrosive and easily volatile chemicals must not be kept inside.

Which power supply arrangement is required?

Use a grounded three-hole socket with a conductor cross-section of at least 0.75 mm², on its own, and add a 1000 W or larger voltage stabilizer if the voltage is unstable.