Hui dian ke ji HDXXVXXA4TK-D Series 4-Channel AC Current/Voltage Acquisition Module User Manual

Hui dian ke ji HDXXVXXA4TK-D series product manual


Hui dian ke ji HDXXVXXA4TK-D Series 4-Channel AC Current/Voltage Acquisition Module User Manual - cover page
Brand
Hui dian ke ji
Category
Other Electronics
Document type
User Manual
Language
Chinese
Pages
4
File format
PDF
File size
872 KB
Published
10 November, 2023
Updated
10 November, 2023
MD5 checksum
0A8B01B68CFD1A1AF5125232510BBCD6

About this manual

This is the Chinese product manual (V3.0, dated 2019-11-18) for the Hui dian ke ji HDXXVXXA4TK-D series four-channel AC current and voltage acquisition module, published by Guangzhou Huidian Information Technology Co., Ltd. It covers precautions, a parameter table, terminal wiring definitions, the Modbus-RTU communication protocol and the module register map.

The parameter table lists a DC 8–28 V supply, RS485 communication with isolation and TVS protection, typical measurement errors at 50 Hz, and operating conditions. The register section defines read-only and read/write Modbus registers for the four channels (current, voltage, apparent power, active power, transformer ratios), and the final page gives notes on derating and range selection. This manual is written in Chinese.

What's inside

  • 注意事项
  • 参数一览表
  • MODBUS-RTU 通信规约
  • 模块接线端子定义
  • 模块寄存器定义
  • 降额与量程选择说明

Specifications

Power supply voltageDC 8 to 28 V
Rated power consumption< 3 W
AC current measurement errortypical ±1% @ 50 Hz
AC voltage measurement errortypical ±1% @ 50 Hz
Apparent power measurement errortypical ±2% @ 50 Hz
Active power measurement errortypical ±4% @ 50 Hz
Communication interfaceRS485, isolated, with TVS protection
Operating temperature-20 °C to 50 °C
Operating humidity5% to 90%, non-condensing
Operating altitude< 2000 m
Rated frequency50 Hz
Current overload capability4 times range for 2 seconds without damage
Voltage overload capability2 times range for 2 seconds without damage
Default communication settings9600, N, 8, 1 (user changeable)
Max nodes on one network32

Frequently asked questions

What power supply does the HDXXVXXA4TK-D module need?

It is powered from DC 8 to 28 V, applied to terminals V+ and V-.

Which communication interface and protocol does the module use?

It uses an isolated RS485 interface with TVS protection and the Modbus-RTU protocol.

What is the default baud rate setting?

The default is 9600, N, 8, 1, and it can be changed by the user.

Can the module measure DC current or voltage?

No. The module cannot be used to measure DC signals or signals containing a DC component; the result would be invalid.