Maschinenfabrik Reinhausen VACUTAP VR Irm 1,600 A On-Load Tap-Changer Operating Instructions

This document is the VACUTAP® VR® instruction manual. The product is an on-load tap-changer with a rated current of 1,600 A and a tap selector level of E 8958777/01 ZH.


Maschinenfabrik Reinhausen VACUTAP VR Irm 1,600 A On-Load Tap-Changer Operating Instructions - cover page
Brand
Maschinenfabrik Reinhausen
Category
transformer
Document type
User Manual
Language
Chinese
Pages
67
File format
PDF
File size
7.4 MB
Published
10 November, 2023
Updated
10 November, 2023
MD5 checksum
FD8B10F4CCA113CAA31AE50E16034DF7

About this manual

The VACUTAP VR Irm 1,600 A is an on-load tap-changer from Maschinenfabrik Reinhausen for regulating a transformer's transformation ratio without interrupting the load. The operating instructions cover intended use, safety, product description, commissioning, operation, troubleshooting, maintenance, disposal, technical data and drawings.

The document is aimed mainly at trained and authorized personnel. The cover identifies the unit as VACUTAP VR Irm 1,600 A with tap selector class E; the validity section names VACUTAP VRL III 1600 on-load tap-changers. It references supporting documents including unpacking instructions, a routine test report, wiring diagram, installation dimensional drawing and order confirmation. This manual is written in Chinese.

What's inside

  • Introduction
  • Safety
  • Product Description
  • Commissioning
  • Operation
  • Troubleshooting
  • Maintenance
  • Disposal
  • Technical Data
  • Drawings

Specifications

Tap selector classE
Current waveformSinusoidal 50/60 Hz AC, symmetrical about the zero axis
Rated through-current switching capability2 times rated through-current Ir at rated step voltage Uir
Short-term voltage allowanceUp to 10% above rated step voltage Uir

Frequently asked questions

What is the VACUTAP VR Irm 1,600 A used for?

It is an on-load tap-changer used to regulate a transformer's transformation ratio without interrupting the load.

What current waveform is the standard version designed for?

It is designed for sinusoidal 50/60 Hz AC current with a curve shape symmetrical about the zero axis.

How far can the rated step voltage Uir be exceeded for a short time?

By up to 10%.

Who are the operating instructions intended for?

They are mainly intended for trained and authorized personnel.