Greenlee 200B-G and 200EP-G Tone Probes Instruction Manual

The document is an instruction manual for the 200B-G Tone Probe and 200EP-G Tone Probe from Greenlee Textron Inc.


Greenlee 200B-G and 200EP-G Tone Probes Instruction Manual - cover page
Brand
Greenlee
Category
Probes
Document type
User Manual
Language
English
Pages
48
File format
PDF
File size
1.7 MB
Published
10 November, 2023
Updated
10 November, 2023
MD5 checksum
EE0563353D833CB7171094D150E83ED5

About this manual

The Greenlee 200B-G and 200EP-G are tone probes used with a Greenlee tone generator to identify and trace wires or cables within a group without damaging the insulation. Both probes have adjustable volume; the 200EP-G also has a visual signal indicator, headset jack, handset connection tabs, and a flashlight.

The manual contains safety alerts and warnings, describes the probe features, and gives step-by-step instructions for pair identification and single conductor/cable tracing. It also lists electrical and physical specifications and covers battery replacement, tip replacement, cleaning, and the one-year limited warranty.

What's inside

  • Description
  • Features
  • Safety
  • Purpose of this Manual
  • Operation
  • Specifications
  • Maintenance
  • Battery Replacement
  • Tip Replacement
  • One-Year Limited Warranty

Specifications

Gain (nominal)30 dB
Input impedance (nominal)100 MΩ
Probe tip resistance (minimum), metal tip0 Ω
Probe tip resistance (minimum), plastic tip300 Ω
Headset connection3.5 mm stereo plug; 8 ohms minimum
BatteryOne 9 VDC (NEDA 1604, JIS 006P, or IEC 6LR61)
Battery life (nominal)50 hours
Length231 mm (9.0”)
Width55 mm (2.2”)
Depth28 mm (1.1”)
Weight145 g (5.2 oz)
Operating and storage temperature0 °C to 50 °C (32 °F to 122 °F)

Frequently asked questions

What battery does the Greenlee 200B-G and 200EP-G tone probe use?

It uses one 9 VDC battery (NEDA 1604, JIS 006P, or IEC 6LR61).

How do I turn on the flashlight on the 200EP-G tone probe?

Press the ON/OFF button further to its second position; reduce pressure slightly to turn the flashlight off.

What is the operating and storage temperature range?

The range is 0 °C to 50 °C (32 °F to 122 °F).

How can I confirm the correct pair when pair tracing?

Separate the two wires; the signal will be as loud on each wire of the pair and will null halfway between them.