Greenlee 77M-G, 77HP-G, and 77HP-G/6A Tone Generators Instruction Manual

Instruction manual for 77M-G, 77HP-G, and 77HP-G/6A Tone Generators.


Greenlee 77M-G, 77HP-G, and 77HP-G/6A Tone Generators Instruction Manual - cover page
Brand
Greenlee
Category
Test Set
Document type
User Manual
Language
English
Pages
72
File format
PDF
File size
2.5 MB
Published
10 November, 2023
Updated
10 November, 2023
MD5 checksum
254E90055C14D917555EEAD2957CB5C9

About this manual

The Greenlee 77M-G, 77HP-G, and 77HP-G/6A Tone Generators are intended to identify the conductor within a bundle, at a cross-connect point, or at the remote end. These testers are housed in high-impact plastic cases and are each powered by one 9 volt battery. Standard test leads include red and black rubber-insulated test clips and a snag-proof, four-conductor modular cord and plug; the 77HP-G/6A offers angled bed-of-nails clips.

This instruction manual covers safety, operation, identifying tip and ring, indicating line condition, verifying lines, supplying talk power, sending tone, and testing for continuity or shorts. It also includes electrical and physical specifications and operating and storage conditions. Replacement manuals are available upon request at no charge at www.greenlee.com.

What's inside

  • Safety
  • Purpose of this Manual
  • Operation
  • Identifying Tip and Ring (Polarity Test)
  • Indicating Line Condition
  • Verifying Lines
  • Supplying Talk Power
  • Sending Tone
  • Testing for Continuity/Shorts Using SHORT Position
  • Specifications

Specifications

Talk Battery4.6 VDC into 600 Ω
Output Power+10 dBm into 600 Ω
Resistive Short Visual Indication<10 kΩ
Resistive Short Audio Indication<200 Ω (77HP-G and 77HP-G/6A only)
Output FrequencyTone: Alternating 890/960 Hz
Warble RateSlow: 1.3 Hz; Fast: 6 Hz
Voltage Protection52 VDC into a 600 Ω circuit
Battery9 VDC (NEDA 1604, JIS 006P or IEC 6LR61)
Battery Life50 hours
Weight128 g (4.5 oz) maximum

Frequently asked questions

What are the tone generators intended to identify?

They are intended to identify the conductor within a bundle, at a cross-connect point, or at the remote end.

How do you select a fast or slow warble tone?

Use the internal slide switch, accessible from the outside with a slender tool, to select fast or slow warble tone output.

What does a bright green LED indicate during a line condition test?

A bright green LED indicates a clear working line with correct polarity.

What battery powers each unit?

Each unit is powered by one 9 volt battery.

Download PDF (2.5 MB)

More Greenlee Manuals


View all Greenlee manuals →