4104-02A Rotary Transformer Torque Sensor Installation and Operating Manual
PCB Load & Torque 4104-02A Rotary Transformer Torque Sensor Installation and Operating Manual covers safety considerations, symbols, repair and maintenance, calibration, returning equipment, and contact information. It also includes a China RoHS 2 disclosure table and a performance specification sheet with supplied accessories.
The manual states that the product is intended for qualified personnel and that field servicing or repair is not recommended. It lists measurement, environmental, electrical, physical, and speed specifications for the sensor.
| Measurement range (full scale capacity) | 1,000 in-lb (113 Nm) |
|---|---|
| Sensitivity (output at rated capacity) | 2.5 mV/V |
| Non-linearity | ≤ 0.05 % FS |
| Hysteresis | ≤ 0.05 % FS |
| Non-repeatability | ≤ 0.02 % FS |
| Environmental overload limit | 3,000 in-lb (340 Nm) |
| Operating temperature range | -65 to 170 °F (-54 to 77 °C) |
| Compensated temperature range | +70 to +170 °F (+21 to 77 °C) |
| Temperature effect on output (maximum) | ±0.002 %Reading/°F (±0.0036 %Reading/°C) |
| Temperature effect on zero balance (maximum) | ±0.002 %FS/°F (±0.0036 %FS/°C) |
| Excitation frequency | 3.28 kHz |
| Bridge resistance | 350 Ohm |
| Excitation voltage | 2 to 10 VAC rms |
| Bridge current (at 5 VAC) | 50 mA |
| Insulation resistance | > 5,000 MOhm |
| Zero balance | ≤ 2 % FS |
| Physical size (shaft length x housing length x housing height) | 10.00 in x 6.00 in x 4.00 in (254.0 mm x 152.4 mm x 101.6 mm) |
| Weight | 18 lb (8.2 kg) |
| Mounting | 1.00 in Dia. Keyed Shaft (25.4 mm Dia. Keyed Shaft) |
| Sensing element | Strain Gage |
| Housing material | Black Oxided Steel |
| Shaft material | Steel |
| Electrical connector | MS3102A-14S-5P |
| Torsional stiffness | 150 kin-lb/radian (16.9 kN-m/radian) |
| Rotating inertia | 0.0026 in-lb-sec^2 (0.0003 N-m-sec^2) |
| Maximum speed | 15,000 RPM |
| Supplied accessories | Model 180-019A 5-socket mating connector (1); Model 8113-105A relay activated precision shunt calibration module (1) |
Beyond routine calibration and battery replacements where applicable, the product requires no user maintenance.
Routine calibration is necessary; PCB recommends calibrating annually, after extreme environmental influence, or before a critical test.
Discontinue use and contact the 24-Hour SensorLine; application engineers provide troubleshooting support 24 hours a day, 7 days a week.
A representative provides a Return Material Authorization (RMA) number, which should be clearly marked on the outside of all returned packages and packing lists.