Rheem RB3AP 12/15/20 L/min Gas Water Heater Installation and User Manual

This document is about the installation and user manual of Rheem gas water heaters.


Rheem RB3AP 12/15/20 L/min Gas Water Heater Installation and User Manual - cover page
Brand
Rheem
Category
Heater
Document type
User Manual
Language
Portuguese
Pages
24
File format
PDF
File size
2 MB
Published
08 November, 2023
Updated
08 November, 2023
MD5 checksum
C0DC3B015DCEC43211BC8C13AA7AF1E0

About this manual

This manual covers Rheem Prestige forced-exhaustion instantaneous gas water heaters for residential use, including models with 12, 15 and 20 L/min capacity, natural gas or LPG, and 127-220 V electrical supply. It includes considerations and recommendations, technical characteristics, an electrical diagram, installation instructions, usage instructions, maintenance and a warranty certificate.

Installation or relocation must be performed by a person trained and authorized by Rheem, following applicable standards. The appliance is intended only for residential water heating, the installation environment must have a minimum gross volume of 6 m3, and installation of the exhaust chimney is mandatory. This manual is written in Portuguese.

What's inside

  • Considerações e recomendações
  • Características técnicas
  • Esquema elétrico
  • Instruções de Instalação
  • Instruções de Uso
  • Manutenção
  • Certificado de garantia

Specifications

Dimensions (12/15 L/min models)540 x 345 x 150 mm
Dimensions (20 L/min models)575 x 355 x 165 mm
Electrical supply127-220 V AC, automatic selection
Safety valve activation time for ignitionApprox. 4 s
Gas connectionG 1/2" male (ISO 228)
Cold water connectionG 1/2" male (ISO 228)
Hot water connectionG 1/2" male (ISO 228)

Frequently asked questions

What happens if electrical power is lost?

The heaters store the last programming in memory and return to that state when power returns; the user only needs to close and reopen the hot water flow.

Is a P13 LPG cylinder recommended?

No; its evaporation capacity is 0.60 kg/h, which can freeze the cylinder battery and carry impurities into the gas valve.

What is the minimum installation room volume?

The installation environment must have a minimum gross volume of 6 m3.

Does the heater require manual voltage selection?

No; the appliance automatically selects 127 or 220 V supply.