This document is the Tankless Gas Troubleshooting Manual for RHEEM Manufacturing Company, providing specifications, sequence of operations, and error code diagnostics for the product.
This manual serves as a training tool and troubleshooting guide for qualified installers and service technicians working on the Rheem SVC 820 Tankless Gas Water Heater. It provides detailed information on the unit's specifications, sequence of operations, and specific maintenance modes.
| Purpose | Domestic Hot Water (DHW) supply for showers, cleaning, and laundry |
|---|---|
| Minimum Water Flow | 0.4 GPM to activate burner |
| Maximum Water Flow | Based on 35 degree rise |
| Working Water Pressure | 14 PSI minimum; 150 PSI maximum |
| Electrical Rating | 120 VAC/60Hz, 3 Amps |
| Freeze Protection | Minus 30F (Without Wind-Chill Factor) with power applied |
The minimum water flow required to activate the burner is 0.4 GPM.
The P1 warning code indicates that the water flow is too low.
The remedy for error code 05 is to remove any vent blockage and ensure venting meets installation requirements.