XK3150-Ex-P intrinsically safe electronic weighing instrument has the following characteristics: 1. Powerful functions 2. Excellent indicators 3. Reliable quality
Locosc XK3150-Ex-P is an intrinsically safe electronic weighing instrument designed for explosive gas environments. The manual describes its safety conditions, explosion protection markings, installation and electrical connections, basic operations, calibration and parameter settings, default parameters, error messages and daily maintenance.
The document lists intrinsically safe parameters for instrument power, printer power, serial ports, 4–20 mA output, I/O ports and load cell interface, along with details for the DE002 battery pack and LP7350-S12 / LP7350-S2x5 intrinsically safe output power supplies. This manual is written in Chinese.
| Accuracy class | 5000 e |
|---|---|
| Resolution | Display: 30,000; internal code: 2,000,000 |
| Measurement speed | 50 ms |
| Sensitivity | 0.3 μV/d |
| Signal range | -30 to 30 mV DC |
| Load cell bridge supply | 5 VDC, 4-wire connection, up to 6 × 350 Ω load cells |
| Operating temperature and humidity | -10 to 40 °C; ≤85% RH |
| Storage and transport temperature | -40 to +70 °C |
| Output signal | RS232, RS485 |
| AC power | Intrinsically safe output power: AC220V to DC12V / AC220V to DC5V |
| Battery | Explosion-proof battery pack: DC7.4V/4000mAh |
| Explosion protection marking | Ex ic IIB T3/T4 Gc |
| Instrument power intrinsically safe parameters | Ui=13V, Ii=500mA, Pi=3.8W, Ci=0μF, Li=0mH |
| Load cell interface intrinsically safe parameters | Uo=5.88V, Io=150mA, Po=0.21W, Co=2.1μF, Lo=1mH |
Only the DE002 battery pack supplied by Ningbo Locosc Precision Technology Co., Ltd. is permitted.
The instrument is rated for an ambient temperature of -10 °C to +40 °C.
No. Charging the battery pack in a hazardous area is not allowed.
With the DE002 battery pack, the marking is Ex ic IIB T3 Gc.