Sinomeasure U-SIN-R6000C-HRCN3 Paperless Recorder User Manual

The U-SIN-R6000C-HRCN3 is a paperless recorder with the following features: 1. Adopts high-performance processor to ensure data accuracy and reliability. 2. Has a variety of data acquisition methods to meet the needs of different users. 3. Has a variety of data analysis functions to help users quickly find the data they need. 4. Has a variety of data display methods to meet the needs of different users. 5. Has a variety of data storage methods to meet the needs of different users. 6. Has a variety of data output methods to meet the needs of different users.


Sinomeasure U-SIN-R6000C-HRCN3 Paperless Recorder User Manual - cover page
Brand
Sinomeasure
Category
Paperless recorder
Document type
User Manual
Language
Chinese
Pages
54
File format
PDF
File size
2.4 MB
Published
08 November, 2023
Updated
08 November, 2023
MD5 checksum
2C86C9344094BE130B7177179C425A3A

About this manual

The Sinomeasure U-SIN-R6000C-HRCN3 is a color paperless recorder with universal inputs that can be configured for standard voltage, standard current, thermocouple, RTD, and millivolt signals. It provides real-time and historical curve displays, bar graph and numeric displays, alarm lists, up to 18 alarm outputs or 12 analog transmission outputs, and up to 8 flow totalizers. It also includes RS232/485 and Ethernet interfaces, a micro printer interface, USB and SD card slots, and sensor power supply.

This third-edition user manual, dated January 2021, describes the product's functions, wiring methods, settings, operation, and troubleshooting. It covers installation precautions, screen operation, configuration, MODBUS RTU communication registers, and warranty and after-sales service. This manual is written in Chinese.

What's inside

  • Product Overview
  • Main Technical Parameters
  • Usage Precautions and Installation
  • Instrument Functions and Operation
  • Real-time Curve Screen
  • Historical Curve Screen
  • Alarm List Screen
  • Configuration Screens
  • Communication
  • Warranty and After-Sales Service

Specifications

Input signalsConfigurable universal inputs: standard voltage, standard current, thermocouple, RTD, and millivolt signals
Measurement accuracy0.2%FS ±1 digit
Sampling period1 second
Display7-inch 800×480 dot-matrix TFT color LCD with LED backlight
Internal storage64 MByte Flash memory
Data backupUSB flash drive and SD card, maximum 8 GB, FAT/FAT32
Record intervalNine settings: 1, 2, 4, 6, 15, 30, 60, 120, and 240 seconds
Power supplyAC 85–264 V, 50/60 Hz; DC 12–36 V
CommunicationRS485/RS232, 1200–57600 bps, standard MODBUS RTU protocol
Alarm outputRelay normally open contact, 1 A/250 VAC resistive load

Frequently asked questions

What is the measurement accuracy of the recorder?

The measurement accuracy is 0.2%FS ±1 digit.

What recording intervals are available?

Nine intervals are available: 1, 2, 4, 6, 15, 30, 60, 120, and 240 seconds.

How can recorded data be backed up?

Data can be backed up to a USB flash drive or SD card with a maximum capacity of 8 GB, using FAT or FAT32 format.

What communication protocol does the RS485/RS232 interface use?

It uses the standard MODBUS RTU protocol, with baud rates from 1200 to 57600 bps.