This manual describes the installation, operation and maintenance of the gearless MGV25M produced by Montanari Giulio & C.
This user guide covers installation, operation and maintenance of the Montanari MGV25M gearless motor. It includes safety notes, transport and storage, component descriptions, lubrication, brake and encoder details, and electrical installation.
The guide also lists operating conditions, handling and assembly instructions, technical characteristics, emergency maneuvers, maintenance points, declaration of conformity, brake certificate, and error and fault information.
| Ambient temperature range | 0°C to +40°C |
|---|---|
| Cooling fan activation temperature | 70°C |
| Winding protection temperature | 130°C |
| Cooling fan supply voltage | 230 Vac |
| Encoder protocol | EnDat 2.2 or Sin-Cos |
| Brake standard | EN81-1 |
| Lubrication | No further lubrication required |
The gearless must be operated in an ambient temperature within 0°C and +40°C.
No. The gearless contains no oil and its bearings are lubricated for the life of the equipment.
The gearless can be supplied with an EnDat 2.2 or Sin-Cos encoder.
The cooling fans are supplied at 230 Vac.