Keli KQC-C(DL) Overload Limiter User Manual

KQC-C(DL) overload limiter is a new type of intelligent overload protector specially used for suspended platforms. It has a series of advantages such as reasonable structure, easy installation, simple debugging and operation, reliable work and high precision.


Keli KQC-C(DL) Overload Limiter User Manual - cover page
Brand
KELI
Category
Monitoring Equipment
Document type
User Manual
Language
Chinese
Pages
19
File format
PDF
File size
518 KB
Published
07 November, 2023
Updated
07 November, 2023
MD5 checksum
F09C65F444EA10FCCADCBDB80F2F7C01

About this manual

The KQC-C(DL) overload limiter is an improved version of the KQC-C limiter, described in the manual as a weight-overload protection device designed for suspended platforms. By setting the instrument's parameters it shows the actual load in real time and monitors two sensors separately; when the load on either sensor reaches the value set for its rated load, it gives an audible and visual alarm and provides a switch output. The unit is compact, has a mounting slot for installation in a control cabinet, and can be connected to a small display panel or a large screen.

The manual covers the instrument's technical parameters, installation and terminal wiring, keypad functions, operation (power-on self-test, manual zeroing, restoring defaults, display switching, self-check), calibration and parameter setting, a description of the parameter setting menu, common faults and their solutions, and a packing list for the KQC-C(DL). This manual is written in Chinese.

What's inside

  • Overview
  • Technical Parameters
  • Installation and Connection
  • Keypad Functions
  • Operating Methods
  • Calibration and Parameter Setting
  • Parameter Setting Menu Description
  • Common Faults and Solutions
  • Packing List

Specifications

Working power supplyAC220V/50Hz
Combined error≤5%F.S.
Bridge supply voltageDC5V
Relay output contact rating10A/250VAC
Input signal range0mV--15mV
Maximum net input signal≤15mV
Display digits4
Large screen output baud rate600bps
Operating temperature-20℃ to 60℃
Instrument dimensions115mm x 90mm x 72mm
Instrument weight0.5kg
Recommended warm-up time≥10min

Frequently asked questions

What power supply does the KQC-C(DL) overload limiter use?

It is powered by AC 220 V at 50 Hz.

What is the operating temperature range of the instrument?

It operates from -20 °C to 60 °C.

Why does the display read 0 after a load is applied?

The sensor wiring may be wrong or the sensor may be installed incorrectly. Check the wiring as shown in the manual and check that the sensor's force point and force direction are correct.

What is included in the KQC-C(DL) packing list?

One KQC-C(DL) overload limiter, one user manual, one certificate, a KQC-C6 buzzer and plug-in terminal blocks; the external display board and its cable are optional.

Download PDF (518 KB)