SDS-S028-005-2201 Brushless Motor Drive (hereinafter referred to as the drive) is mainly used for brushless motor drive and brushed motor drive. The motor position sensor interface is SSI/BISS absolute encoder.
This is the Chinese user manual for the Sengle SDS-S028-005-2201 brushless motor driver, a board used to drive brushless and brushed motors with an SSI/BISS absolute encoder as the motor position sensor interface. The manual gives the electrical specifications, the outline dimensions, the electrical interconnection diagram and the pin definitions of the two on-board connectors (J6 for power and motor, J3 for encoder and communication).
The second half of the document describes the RS422 communication protocol, including the 7-byte data frames sent by the driver board and received from the host, the status word bit definitions, the checksum, and the control function codes for torque commands. It then lists the three control methods (RS422 communication, CAN and PWM duty-cycle control, the last two marked as reserved), the related parameter numbers such as P5-10 baud rate and P5-11 communication format, example test frames, and the PE-10 encoder type setting. This manual is written in Chinese.
| Power input | 28 V single supply, wide range DC 20 V to DC 36 V |
|---|---|
| Output current | 5 A continuous, 15 A peak |
| Encoder interface | 1 channel BISS-C/SSI encoder interface (+5V, GND, CLK+, CLK-, DAT+, DAT-) |
| Motor interface | 1 three-phase brushless motor (U, V, W) |
| Dimensions | 50 mm × 40 mm × 18 mm (L × W × H) |
| Default RS422 baud rate | 115200 bps |
| RS422 data format | 8 data bits, no parity, 1 stop bit (8, N, 1) |
| Encoder type parameter PE-10 | 0x400 = SSI encoder, 0x500 = BISS encoder, 0x600 = RS422 encoder |
It uses a single 28 V supply and accepts a wide DC input range of DC 20 V to DC 36 V.
Through parameter PE-10: 0x400 for an SSI encoder, 0x500 for a BISS encoder and 0x600 for an RS422 encoder.
There are three: RS422 communication control, CAN communication control and PWM duty-cycle control; the CAN and PWM sections are marked as reserved.
The default baud rate is 115200 bps with the format 8, N, 1 (8 data bits, no parity, 1 stop bit).