Zhejiang ChenXin Machine Equipments Co.,Ltd. LQ-T200D multifunctional hydraulic stripper is suitable for the stripping of soil compaction specimens, Marshall compaction specimens and unconfined compressive strength specimens. It adopts AC hydraulic power unit and the international popular G-type gear pump. It has the characteristics of compact structure, large stripping force, low noise, simple operation, stable and reliable performance, beautiful appearance, and is currently the most advanced model in China.
This is the Chinese user manual for the LQ-T200D multifunctional hydraulic stripper (脱模器) made by Zhejiang ChenXin Machine Equipments Co., Ltd. The machine is used to press compacted specimens out of their molds: soil compaction specimens, Marshall compaction specimens and unconfined compressive strength specimens. It uses an AC hydraulic power unit with a G-type gear pump.
The manual gives the main technical parameters (AC380V 50Hz three-phase supply, 0.75 kW motor, 8 L oil tank, 16 MPa design pressure, about 90 mm/min lifting speed, 240 mm maximum demolding height), then explains adjustment of the control knob and power supply, the demolding procedure, cautions about hydraulic oil and running time, and the packing list. This manual is written in Chinese.
| Rated voltage | AC380V 50Hz (three-phase four-wire, neutral required) |
|---|---|
| Motor | AC380V three-phase 0.75KW |
| Solenoid valve | AC220V two-way solenoid valve |
| Oil pump | G-type gear pump |
| Oil tank capacity | 8L |
| Design pressure | 16MPa |
| Lifting speed | about 90mm/min |
| Maximum demolding height | 240mm |
| Demolding sizes | ¢100, ¢150 (soil compaction); ¢50, ¢100, ¢150 (unconfined); ¢101.6, ¢152.4 (Marshall) |
| Recommended hydraulic oil | N46# anti-wear hydraulic oil, filtered through 30µm |
It needs a 380V, 50Hz three-phase four-wire supply, and the fourth wire must be a neutral line for the internal solenoid valve. A single-phase motor version is made to order at 220V, 50Hz.
The supply phase sequence is probably wrong, making the oil pump run backwards, or the neutral line is wrong so the solenoid valve does not act. Switch off, check the neutral line, or swap the position of any two phase wires.
N46# anti-wear hydraulic oil is recommended, filtered through a 30µm filter when filling. In cold regions a low-temperature anti-wear hydraulic oil should be used instead.
The packing list includes one main unit, ¢100 top block, support plate and top plate, one ¢150 top block, and optional ¢50 top block and top plate, plus the manual, certificate and packing list.