ChenXin MSY-90 Microcomputer Marshall Asphalt Mixture Stability Tester Instruction Manual

Instruction manual of microcomputer Marshall asphalt mixture stability tester, mainly including product technical parameters, operation instructions, printing, manual rise / fall, calibration and so on


ChenXin MSY-90 Microcomputer Marshall Asphalt Mixture Stability Tester Instruction Manual - cover page
Brand
ChenXin
Category
Other products
Document type
User Manual
Language
Chinese
Pages
4
File format
PDF
File size
3.2 MB
Published
30 October, 2023
Updated
30 October, 2023
MD5 checksum
3680E762E6C3D9F3FBD129D37A345536

About this manual

This manual describes the ChenXin MSY-90 microcomputer Marshall asphalt mixture stability tester, including its main technical parameters, operating steps, printing, manual raising and lowering, and calibration procedure.

The document also includes a packing list and a certificate of conformity with inspection items such as maximum load, test space, specimen size, motor power, flow value range, rise rate, and noise. This manual is written in Chinese.

What's inside

  • Main technical parameters
  • Operating instructions
  • Test procedure
  • Printing
  • Manual rise and lowering
  • Calibration
  • Packing list
  • Certificate of conformity
  • Electrical control section description

Specifications

Pressure measurement range0-50 kN
Pressure display unit0.01 kN (10 N)
Flow value measurement range0-15.00 mm
Working voltage220 V, 50 Hz
Working temperature5-35 °C (recommended 10-30 °C)
Maximum load50 kN
Test space300 mm
Specimen size101.6-152.4 mm
Motor power370 W
Flow value range (certificate)0-10 mm
Rise rate50 ± 5 mm/min
Noise≤75 dB

Frequently asked questions

What is the pressure measurement range of the MSY-90?

The pressure measurement range is 0-50 kN, displayed in 0.01 kN (10 N).

What is the working voltage of the MSY-90?

The working voltage is 220 V at 50 Hz.

What happens if specimen pressure exceeds 5 T?

The instrument enters overpressure protection, stops the test, and lowers the control part to a certain height.

How are calibration passwords entered?

The pressure calibration password is 0001 and the displacement calibration password is 0002.