Keli SJ-03/SJ-04 Dry Powder Mortar Tank Control Box User Manual

SJ-03/SJ-04 Dry powder mortar tank control box user manual


Keli SJ-03/SJ-04 Dry Powder Mortar Tank Control Box User Manual - cover page
Brand
KELI
Category
Automation control Equipment
Document type
User Manual
Language
Chinese
Pages
4
File format
PDF
File size
158 KB
Published
07 November, 2023
Updated
07 November, 2023
MD5 checksum
FE225C08DA8009733F0A68DA92D20E7C

About this manual

This is the December 2012 Chinese user manual from Ningbo Keli Sensing Technology Co., Ltd. for the SJ-03/SJ-04 dry powder mortar tank control box (干粉砂浆罐控制箱). It opens with special notices on the operating environment, the three-phase five-wire 380V±15% power requirement, and safety advice to cut the main power before maintenance or during long periods of non-use. It also notes that the SJ-03 uses a weighing instrument without a GPRS+GPS module, while the SJ-04 uses one that includes GPRS+GPS, and gives the enclosure size as 330 x 500 x 210 mm with 0.8 mm wall thickness.

The manual then explains how to use the box: switching the manual/automatic mode, setting the T1 and T2 time relays (1s-99h) with the DIP switches, and starting or stopping operation with the start and stop buttons. T1 cuts the system power automatically, T2 sets the vibration motor cycle (work time above, stop time below), and T1 must be longer than the total T2 time. The remaining pages describe the control sequence, the power connector at the bottom of the box, placing the GPS antenna outside the enclosure on the SJ-04, the outline dimensions drawing, and the packing list (control box, this manual, and the KL3101-S1 instrument manual). This manual is written in Chinese.

What's inside

  • 特别提醒 (Special notices)
  • 控制箱电源要求 (Power supply requirements)
  • 控制箱的使用 (Using the control box)
  • 时间继电器设置 (Time relay settings)
  • 手动/自动模式 (Manual and automatic modes)
  • 控制过程 (Control sequence)
  • 动力电源接口说明 (Power connector)
  • 箱体尺寸 (Enclosure dimensions)
  • 装箱清单 (Packing list)

Specifications

Operating temperature0°C to 40°C
Operating humidityRelative humidity below 70%, without condensation
Power supplyThree-phase five-wire, 380V ±15%
Enclosure dimensions (L x W x D)330 x 500 x 210 mm
Enclosure thickness0.8 mm
Time relay range (T1, T2)1 s to 99 h

Frequently asked questions

What is the difference between the SJ-03 and SJ-04 control boxes?

The weighing instrument used with the SJ-03 does not include a GPRS+GPS module, while the one used with the SJ-04 does.

What power supply does the control box require?

It normally uses a three-phase five-wire 380V ±15% supply; if the voltage is unstable or fluctuates more than ±15%, a voltage stabilizer is recommended.

What time range can the time relays be set to?

Both T1 and T2 can be set from 1 s to 99 h using the DIP switches, and T1 must be longer than the total T2 time.

Where should the GPS antenna be placed on the SJ-04?

Place the GPS antenna outside the box to make satellite positioning easier.