The wind sensor combination OMC-160 consists of the wind speed sensor and wind direction sensor. The system is robust, lightweight, corrosion resistive and easy to install.
This is the installation and technical user manual (version 2.04, dated 28-11-2013) for the OMC-160 wind sensor combination from Omni Instruments. The OMC-160 combines a stainless-steel rotary-cup wind speed sensor with a stainless-steel wind vane direction sensor; a microprocessor converts the optical pulses and resolver position into a combined digital serial current loop signal in ASCII code. The manual covers mechanical and electrical installation, commissioning and the LED align procedure, sensor body maintenance and spare parts, output formats including NMEA, internal wiring and connections, dimensions and the declaration of conformity.
Data in the manual include an 8 to 30 VDC supply drawing 60 mA, a 20 mA current loop output with NMEA-0183 version 2.30, a weight of 6.5 kg, dimensions of 865x248x465 mm, IP65 moisture protection and an operating temperature range of -25 to 70 degrees C. Optional de-icing heaters of 24 Volts ac or dc, 35 Watt are described, and a jumper on terminals 13 and 14 selects between the OMC-160 format at 300 baud and the NMEA format at 4800 baud.
| Power supply | 8 to 30 VDC, 60 mA |
|---|---|
| Output | Current loop ASCII coded output 20 mA, NMEA-0183 version 2.30 |
| Weight | 6.5 kg |
| Dimensions | 865x248x465 mm (DxWxH) |
| Mounting pole | max. 65 mm diameter |
| Operating temperature | -25 to 70 °C |
| Moisture protection | IP65 |
| Humidity | 10 to 95% |
| Accuracy, wind speed | better than 2% FRO |
| Accuracy, wind direction | better than 3 degrees |
| Speed range | 0.3 to 75 m/s |
| Cup unit | 3 helicoid cups, 80 mm diameter, 130 mm outer spin diameter, 8 pulses/rotation |
| De-icing heaters (option) | 24 Volts ac or dc, 35 Watt, thermostat controlled |
| Signal cable length | up to 1200 meters |
In land-based systems the OMC-160 should be aligned to North; after alignment it reports absolute wind direction.
It requires a 4-core cable (2 twisted pairs, 0.75 mm2, common screen); with de-icing heaters a 6-core cable is needed.
It sets different output types: with the jumper in place the baud rate is 300 baud with the OMC-160 format, and with the jumper removed it is 4800 baud with the NMEA format.
The precision ball bearings are the only components likely to require replacement due to normal wear, and replacement should only be attempted by a qualified technician.