This document is a user manual for an electric water heater, which introduces the identification of the parts of the electric water heater and safety information.
This is the user manual for the Electrolux electric water heater models EWE351PX-DWX5 and EWE451PX-DWX5. It starts with a parts identification drawing that names the front cover, LED indicators, test/reset button, temperature control knob, 3 in 1 stop valve, mesh filter, handshower, shower bracket holder, PVC hose, heater base, thermostat, heater tank, PCB boards, TRIAC, reed switch assembly and the water inlet and outlet connections.
The manual then sets out safety information, including earthing requirements and the conditions under which the power supply must be switched off, followed by step-by-step unit installation, the plumbing procedure, and the electrical installation with a method of alignment for replacing the front cover. A cable size table lists power, current, conductor size, fuse/switch and MCB ratings for the different models, and a shower set installation diagram is included.
| Rated voltage | 220V ~ 50/60 Hz |
|---|---|
| Voltage (Malaysia model) | 240V ~ 50/60 Hz |
| Model power ratings | 2.4kW, 3.5kW, 3.8kW, 4.5kW, 4.8kW models |
| Cable size for 2.4kW-4.8kW models | 2.5mm² double insulation cable |
| Cable size for 3.6kW and 6.0kW models | 4mm² double insulation cable |
| Minimum water flow rate | 2.0 litre/min |
| Maximum working pressure | 6 bars |
| ELCB trip current | leakage over 15mA |
| Recommended mounting height | 1.5 m above the bathroom floor |
The heater operates at a minimum water flow rate of 2.0 litre/min and will not function if the flow is insufficient.
No. The heater must be permanently connected to the direct main line supply, and a plug and socket is not recommended.
The heater tank must be filled up with water first to prevent dry burnt damage to the heating element.
Immediately switch off the power supply and contact the Electrolux Consumer Care Centre; do not attempt to repair the heater yourself.