Electrolux EWE351PX-DWX5 EWE451PX-DWX5 Electric Water Heater User Manual

This document is a user manual for an electric water heater, which introduces the identification of the parts of the electric water heater and safety information.


Electrolux EWE351PX-DWX5 EWE451PX-DWX5 Electric Water Heater User Manual - cover page
Brand
Electrolux
Category
Water heater
Document type
User Manual
Language
English
Pages
2
File format
PDF
File size
4.3 MB
Published
05 November, 2023
Updated
05 November, 2023
MD5 checksum
1CD672A8AA4B755308CDA9A2257C6B67

About this manual

This is the user manual for the Electrolux electric water heater models EWE351PX-DWX5 and EWE451PX-DWX5. It starts with a parts identification drawing that names the front cover, LED indicators, test/reset button, temperature control knob, 3 in 1 stop valve, mesh filter, handshower, shower bracket holder, PVC hose, heater base, thermostat, heater tank, PCB boards, TRIAC, reed switch assembly and the water inlet and outlet connections.

The manual then sets out safety information, including earthing requirements and the conditions under which the power supply must be switched off, followed by step-by-step unit installation, the plumbing procedure, and the electrical installation with a method of alignment for replacing the front cover. A cable size table lists power, current, conductor size, fuse/switch and MCB ratings for the different models, and a shower set installation diagram is included.

What's inside

  • Parts Identification
  • Safety Information
  • Electric Water Heater Unit Installation
  • Plumbing Procedure
  • Electrical Installation
  • Method of Alignment When Replacing Front Cover
  • Table 1 - Cable Size Table
  • Shower Set Installation Diagram

Specifications

Rated voltage220V ~ 50/60 Hz
Voltage (Malaysia model)240V ~ 50/60 Hz
Model power ratings2.4kW, 3.5kW, 3.8kW, 4.5kW, 4.8kW models
Cable size for 2.4kW-4.8kW models2.5mm² double insulation cable
Cable size for 3.6kW and 6.0kW models4mm² double insulation cable
Minimum water flow rate2.0 litre/min
Maximum working pressure6 bars
ELCB trip currentleakage over 15mA
Recommended mounting height1.5 m above the bathroom floor

Frequently asked questions

What is the minimum water flow rate needed for the heater to work?

The heater operates at a minimum water flow rate of 2.0 litre/min and will not function if the flow is insufficient.

Can the water heater be connected with a plug and socket?

No. The heater must be permanently connected to the direct main line supply, and a plug and socket is not recommended.

What must be done before turning on the power supply?

The heater tank must be filled up with water first to prevent dry burnt damage to the heating element.

What should I do if the ELCB trips and the indicator does not light up?

Immediately switch off the power supply and contact the Electrolux Consumer Care Centre; do not attempt to repair the heater yourself.