This document is a maintenance manual for gear drive units, including disassembly and assembly instructions for gear drive units
This Chemineer 380 HT Gear Drive Maintenance Manual provides instructions for disassembly and assembly of the HT gear drive in case sizes 1, 2, and 3. It states that, apart from periodic lubrication covered in the agitator manual, no routine operational gear drive maintenance is required.
The manual covers the gear drive, spiral bevel pinion cartridge, output shaft, upper bearing cap, and input shaft, along with an item list of parts. It also includes tables for bolt tightening torque and backlash setting and a supplemental information section.
| Case sizes | 1, 2, 3 |
|---|
The manual covers case sizes 1, 2, and 3.
No. Other than periodic lubrication defined in the agitator manual, no routine operational gear drive maintenance is required.
Gear tooth wear patterns, shaft/bearing end play, alignment, bolting, and the condition of all seals should be checked.
All bearings, lip seals, o-rings, shims, and gaskets should be replaced with new parts.