This file is the product manual for FST600-6JG infrared thermometer. It introduces the working principle, application area, product characteristics, technical indicators, electrical interface and other information.
The FST600-6JG is a short-wave, coaxial laser, online infrared thermometer from Hunan Firstrate Sensor Co., Ltd. It calculates a surface temperature from the object's infrared radiation without contact, uses a class 2 laser for coaxial aiming to mark the center of the measurement spot, and provides a two-wire 4–20 mA current output for installation in industrial environments.
This V1.0 product manual covers the product overview and application fields, key features, technical specifications, the electrical connector and cable color assignments, optics and spot size, mounting through a 46 mm hole with an M45×1.5 nut, the yellow SET button for the laser and emissivity setting, temperature display behavior, and maintenance, storage and safety notes. This manual is written in Chinese.
| Supply voltage | 24V DC |
|---|---|
| Output signal | 4-20mA, two-wire current output, max. load 750Ω |
| Spectral range | 1.6um/1um |
| Temperature range | 300-1400℃ / 600-2000℃ (FST600-6JG-30140 / FST600-6JG-60200) |
| Optical resolution | 200:1 |
| Response time | 10ms (95%) |
| Accuracy | ±1% of reading or ±1℃, whichever is greater |
| Repeatability | ±0.5% of reading or ±0.5℃, whichever is greater |
| Emissivity | 0.5-1.00 (default 0.95) |
| Aiming | Laser aiming, class 2 laser, max. output power 1mW, 650nm |
| Dimensions | Φ45mm×150mm |
| Weight | Approx. 300g |
| Operating / storage temperature | -10~60℃ operating, -20~80℃ storage |
| Protection class | IP65 (NEMA-4) |
The temperature range is 300-1400℃ or 600-2000℃, corresponding to models FST600-6JG-30140 and FST600-6JG-60200.
It gives a 4-20mA two-wire current output with a maximum load of 750Ω.
Hold the yellow SET button for 3 seconds and release it; the emissivity is shown, and each press changes it by 0.05. If left untouched, it returns to the temperature reading after 10 seconds.
It is fixed through a 46mm mounting hole with a nut (M45×1.5), optionally using a mounting bracket; the focus is adjusted by the thread on the lens until the laser spot is brightest and smallest.