2500 gallon filter pump user manual, introduces the use methods, installation methods and precautions of the product
This manual provides comprehensive safety and operating instructions for the Bestway 58391 2500 gallon filter pump (model 58391). It includes important safety warnings, such as electrical requirements (RCD ≤30 mA, grounding), placement rules (pump plug ≥3.5 m from pool, unit ≥2 m from pool), and usage restrictions (no operation while people are in the pool, above-ground pools only).
The document also details installation steps (base fixing with 18 kg minimum weight, 256 mm hole spacing), maintenance recommendations (daily filtration ≥8 hours, filter cartridge replacement every two weeks), and storage guidelines (disassemble below 10 °C, store dry at 10–38 °C). Warranty information and applicable Chinese standards (GB 4706.1, GB 4706.66, etc.) are listed at the end. This manual is written in Chinese.
| Maximum Total Head | 1.5 m |
|---|---|
| RCD Rated Residual Operating Current | ≤30 mA |
| Pump Plug Distance from Pool | ≥3.5 m |
| Unit Distance from Pool | ≥2 m |
| Minimum Base Weight | 18 kg |
| Base Mounting Hole Spacing | 256 mm |
| Recommended Daily Filtration Time | ≥8 hours |
| Filter Cartridge Replacement Interval | Every 2 weeks |
| Disassembly Temperature Threshold | <10 °C |
| Storage Temperature Range | 10–38 °C |
The maximum total head (Hmax) is 1.5 meters.
The pump plug must be at least 3.5 meters from the pool.
At least 8 hours per day to ensure clear pool water.
Every two weeks for optimal performance and hygiene.
The base must weigh at least 18 kg to prevent the pump from tipping.