Zhongdi Hengda FBG-GJ01 Fiber Optic Grating Steel Gauge User Manual

FBG-GJ01 Steel bar gauge is suitable for long-term embedding in the interior of concrete structures to measure the steel stress inside the structure. Using wavelength demodulation technology, high measurement accuracy, no electromagnetic interference, IP67 protection, can adapt to high humidity environment.


Zhongdi Hengda FBG-GJ01 Fiber Optic Grating Steel Gauge User Manual - cover page
Brand
Zhongdi Hengda
Category
sensor
Document type
User Manual
Language
Chinese
Pages
4
File format
PDF
File size
220 KB
Published
03 November, 2023
Updated
03 November, 2023
MD5 checksum
A9CFCF71FD44FFD4C6C90389FE79AE2B

About this manual

The FBG-GJ01 is a fiber optic grating steel gauge from Wuhan Zhongdi Hengda Technology Co., Ltd. It is intended for long-term embedding in concrete structures to measure internal rebar stress. The manual covers its features, main technical specifications, installation steps and site installation precautions.

It describes pre-installation reading checks, welding the gauge parallel to the rebar, cable routing and fixing, and the formula for calculating rebar stress from wavelength readings. A troubleshooting table gives causes and remedies for missing spectra, low peak energy and missing strain readings. This manual is written in Chinese.

What's inside

  • Overview
  • Features
  • Main technical specifications
  • Pre-installation test
  • Sensor installation
  • Cable installation
  • Site installation precautions
  • Calculation formula
  • Troubleshooting

Specifications

Standard range0 to 400 MPa
Measurement accuracyLess than 1% FS
Resolution0.1% FS
Wavelength range1525 nm to 1565 nm
Grating reflectivityGreater than 85%
Measurement timeLess than 1 s
Installation formEmbedded
Fiber outputSingle-mode single-core, double-ended fiber output
Operating environment-30 °C to +80 °C, humidity below 95% non-condensing
Protection ratingIP67

Frequently asked questions

What is the FBG-GJ01 used to measure?

It measures rebar stress inside concrete structures, where it is designed to be embedded for the long term.

What is the standard measuring range and accuracy?

The standard range is 0 to 400 MPa, and the accuracy is less than 1% FS.

How is the gauge welded to the rebar?

It is welded from both ends toward the middle, with 160 mm of weld at each end.

What is the minimum cable routing diameter?

The cable routing must not be smaller than 20 mm in diameter.