AMD mixer installation, operation and maintenance instructions
This Grundfos manual provides installation, operation, and maintenance instructions for the AMD mixer series used in pump station and sewage pools. The mixers are designed for mixing applications in low to medium viscosity liquids up to 500 mPas, such as homogenization and keeping solids in suspension.
It covers model designation, nameplate identification, safety requirements, storage, installation, electrical connection, startup, maintenance, fault finding, spare parts, technical data, and recycling. The document applies to AMD mixers with 50/60 Hz power supply. This manual is written in Chinese.
| Maximum dynamic viscosity | 500 mPas |
|---|---|
| Liquid temperature | 5-40 °C |
| Maximum density | 1060 kg/m3 |
| Power cable length | 10 m |
| Maximum tilt angle | ± 40° |
| Oil type | SHELL Ondina X420 |
The maximum dynamic viscosity is 500 mPas.
The mixer is supplied with a 10-meter power cable.
Viewed from the propeller end, the rotation direction must be clockwise.
The maximum allowable tilt angle is ± 40 degrees.