Technical manual of Black Bruin S series hydraulic motors, which introduces product features, operating instructions, installation methods, etc.
This product manual covers Black Bruin S series hydraulic motors, which the manual states are designed for industrial use. It explains the motor's operating principle and product identification code, and provides technical data, interface dimensions, system design guidance, installation and operating instructions, and storage instructions.
Safety instructions cover personal protective equipment, lifting and supporting the motor, pressurized hydraulic lines, and burn hazards from hot oil and motor surfaces above 60 °C (140 °F). The manual also notes warranty terms, product identification on the nameplate, break-in requirements, working-temperature limits, and removal procedures, and ends with Black Bruin Inc. contact details. This manual is written in Chinese.
| Maximum permitted intermittent operating temperature | 85 °C (185 °F) |
|---|---|
| Minimum permitted operating temperature | -35 °C (-31 °F) |
| Recommended maximum working temperature for service life | 70 °C (158 °F) |
| Maximum temperature difference between motor and hydraulic oil | 60 °C (140 °F) |
| Minimum break-in period | 8 hours |
| Maximum power output during break-in | 50% of maximum motor power |
The manual states that Black Bruin S series hydraulic motors are designed for industrial use.
The break-in period should last at least eight hours, and power output should remain below 50% of the motor's maximum power.
The maximum permitted intermittent working temperature is 85 °C (185 °F).
The manual says the motor can be stored for about two years, but storage conditions have a major influence and the time is for reference only.