This is a manual for installing plasterboard
This manual is intended for use by plastering contractors and builders. It outlines recommended methods for installation, jointing and finishing of USG Boral plasterboard linings in non-fire rated residential construction.
It covers plasterboard properties, design considerations, framing, fixing, ceilings, walls, wet areas, curves, cornices, jointing and decorating. Installation specifications apply to Level 4 finish unless noted otherwise.
| Sheet widths | 1200 mm and 1350 mm |
|---|---|
| Thermal coefficient of linear expansion | 16.2 x 10-6 mm/(mm°C) at 4 to 38°C |
| Hygrometric coefficient of expansion | 7.2 x 10-6 mm/mm%RH at 5 to 90%RH |
| R-value (10 mm STANDARD/SHEETROCK) | 0.056 m2 K/W ±10% |
| R-value (13 mm STANDARD/SHEETROCK) | 0.073 m2 K/W ±10% |
| R-value (10 mm FIBEROCK) | 0.038 m2 K/W ±10% |
| R-value (13 mm FIBEROCK) | 0.049 m2 K/W ±10% |
| Fire hazard classification | Group 1 |
| Smoke growth rate index | Less than 100 |
| Average specific extinction area | Less than 250 m2/kg |
| Paper liner recycled content | 100% recycled waste paper fibre |
| FIBEROCK recycled content | 95% |
| Embodied energy | 4.4 MJ/kg |
It is intended for use by plastering contractors and builders.
They apply to Level 4 finish unless noted otherwise.
It is comprised of a specially formulated gypsum core encased between heavy duty paper liners.