Alarmtech CD470 Shock and Vibration Detector Data Sheet and Installation Manual

CD 470 is a shock- and vibration detector with 3 separate detection channels: an integration channel / saw channel for weak signals with long duration, a counting channel that senses strong impact on the monitored surface and an explosion channel which senses very strong signals from e.g. an explosion.


Alarmtech CD470 Shock and Vibration Detector Data Sheet and Installation Manual - cover page
Brand
Alarmtech
Category
Anti-Theft Devices
Document type
Installation Guide
Language
English
Pages
2
File format
PDF
File size
515 KB
Published
03 November, 2023
Updated
03 November, 2023
MD5 checksum
79C6FEED77C18697E2A504BE831D68AB

About this manual

The Alarmtech CD470 is a shock- and vibration detector for monitoring against attacks with mechanical tools. It has three separate detection channels: an integration/saw channel for weak signals with long duration, a counting channel for strong impact, and an explosion channel for very strong signals such as an explosion.

The detector uses a piezoelectric sensor and has built-in alarm and tamper relays, allowing direct connection to an alarm central unit without an analyzer unit. The document covers mounting, six screw terminals, DIP-switch settings, detection radius, commissioning and adjustment, technical data, and ordering information.

What's inside

  • Description
  • Features
  • Operating Principle
  • Mounting
  • Connections
  • DIP-Switch
  • Detection Radius
  • Commissioning and Adjustment
  • Technical Data
  • Ordering Information

Specifications

Detection radiusUp to 3 m
Input voltage8–15 VDC (DAY mode), 6 VDC (NIGHT mode)
Max ripple0.2 Vpp at 12 V
Quiescent current8.0 mA at 12 V
Alarm current7.1 mA at 12 V
Alarm outputRelay, max 50 V / 120 mA, R < 30 Ω
Alarm time4 s with Auto Reset, or latching
Operating temperature range-40°C to +55°C
Operating humidityMax 95% RH
HousingWhite ABS plastic, IP 42
Size20 x 23 x 80 mm (H x D x W)
ApprovalsEN 50131-2-8 Grade 3, SSF 1014-5 Klass 3, VdS 2480 Klasse B, INCERT B-582-1001

Frequently asked questions

What detection channels does the CD470 have?

It has three separate detection channels: an integration/saw channel for weak long-duration signals, a counting channel for strong impacts, and an explosion channel for very strong signals.

Can the CD470 be connected directly to an alarm central unit?

Yes. It has built-in relays for the alarm and tamper outputs, so no analyzer unit is necessary.

What happens at 6 Vdc on the power input?

NIGHT mode is active and the LED is switched off in case of alarm or fault.

What is the cover radius of the CD470?

The cover radius is up to 3 m.

Download PDF (515 KB)

More Alarmtech Manuals


View all Alarmtech manuals →